FDA因微生物污染无菌溶液向美国兽药生产商发出警告信

FDA Warning Letter for a microbially contaminated Sterile Solution

AI 导读

FDA因超过95例由微生物污染无菌溶液引发的事件,向一家美国兽药生产商发出警告信,该企业已于2026年1月召回多个可能受污染的批次。标注为无菌的溶液实际检出多种活微生物,包括Purpureocillium lilacinum等真菌,FDA同时指出其关节注射的超说明书使用与使用说明不足。

推荐理由

材料列出警告信中的无菌污染证据与合同生产商现场缺陷,便于对照环境监测、厂房维护和更衣环节的检查关注点。

正文 · 原文

Not as the result of an inspection, but due to more than 95 incidents caused by a microbially contaminated sterile solution, the FDA issued a Warning Letter to a US-based veterinary manufacturer. According to the FDA, product samples were collected, the manufacturing facility was inspected, and epidemiological and clinical evidence from the more than 95 individual cases was evaluated. As stated by the FDA, this contamination led to the highest number of deaths ever recorded for a single animal species in connection with a sterile product regulated by the FDA for veterinary use. The manufacturer subsequently recalled several batches of potentially contaminated sterile sodium hyaluronate solution in January 2026, which had been produced by a contract manufacturer.The FDA found that the product labelled as a "sterile solution" was in fact not sterile. Several viable microbial organisms were detected, including the fungal species Purpureocillium lilacinum, Paraisaria heteropoda, Gongronella lacrispora, Purpureocillium sodanum and Isaria takamizusanensis. The FDA also addresses an off-label use as a joint injection and the lack of adequate instructions for use. Injecting a microbially contaminated product into a joint space can lead to severe inflammation and infection. According to the FDA, animals had to be euthanised in individual cases.The inspection subsequently carried out at the contract manufacturer revealed unhygienic conditions. The FDA cites the following examples: Inadequate cleaning and disinfection of the manufacturing environment (no use of a sporicidal agent) Inadequate monitoring of differential pressures Inadequate environmental monitoring (no sampling for viable particles or microorganisms) No personnel monitoring for viable microorganisms No smoke studies to demonstrate airflow in the ISO 5 area Poor structural condition and maintenance (cleanroom in a warehouse-style setting, several examples of uncleanliness and "state of disrepair") Inadequate gowning (exposed skin, non-sterile clothing components) Inadequate media fills, as these did not reflect real productionThe FDA states that the company did not exercise adequate quality oversight over the contract manufacturer.On the FDA website you will find the full Warning Letter.

来源:ECA GMP News · gmp-compliance.org