ECA GMP News·AI 评分64

USP 在 PF 52(1) 提议新增 <86> 重组试剂内毒素检查,拟适用于注射用水与纯蒸汽专论

Endotoxins Testing: Potential Change for WFI and Steam in the USP

AI 导读

USP 在药典论坛 PF 52(1)(2026 年 1 月)提议新增 <86> 重组试剂细菌内毒素检查,作为经典 <85> 之外的替代方法。若获通过,注射用水、无菌注射用水、血液透析用水和纯蒸汽等专论可纳入 <86>,内毒素限度保持不变,但需由用户进行产品专属验证,包括评估供应商的主要验证数据和内部适用性试验,并参考 <1226> 选择验证实验。

正文 · 原文

In Pharmacopeial Forum (PF) 52(1), January 2026, the USP proposes to add an alternative endotoxins test: <86> Bacterial Endotoxins Test Using Recombinant Reagents, alongside the classical <85> Bacterial Endotoxins Test. If adopted, this could affect, among others, the monographs for Water for Injection, Sterile Water for Injection, Water for Hemodialysis, Pure Steam and other sterile waters. The endotoxins limit would remain unchanged.Monograph <86> is based on animal-free, recombinant reagents and is already official in the USP. The proposed change would, for the first time, allow the specific application of <86> in USP water monographs. However, this requires product-specific verification by the user, including assessment of the supplier's primary validation data and internal suitability tests. For the selection of verification experiments, reference is made to <1226> Verification of Compendial Procedures. Regulatory authorities may request additional data, such as comparative studies between <86> and <85>.The proposal is open for comment. If accepted, the use of <86> could be included in the relevant USP water monographs in 2027. Pharmacopeial Forum (PF) is a free, bimonthly online publication in which the USP posts proposed revisions to the USP-NF for public comment (registration required).

来源:ECA GMP News · gmp-compliance.org