Sanofi 与 Ypso-Facto 发表模拟辅助多柱色谱工艺开发研究,面向重组蛋白疫苗生产
Simulation-Aided Development of Multicolumn Chromatography Processes for Protein-Based Vaccine Production
Sanofi 与 Ypso-Facto 发表研究,用机理模型支持重组蛋白疫苗生产的多柱亲和层析捕获步骤开发。研究在实验室规模采用三柱、两根位于上样区的构型,将上样量确定为 7 CV;放大到处理 10 L 澄清收获液时,实验与模拟收率分别为 85.6% 和 86.6%。相较单柱单次上样,多柱配置可将总柱体积降低近 20 倍,机理建模所需实验约为响应面 DoE 的三分之一。

https://stock.adobe.com
Vaccines based on recombinant proteins represent a diverse class of immunological products, with antigenic proteins exhibiting significant variability depending on the target. Such proteins can differ substantially in terms of molecular weight, isoelectric point, tertiary structure, and glycosylation profiles. Furthermore, they are produced using various expression systems, including prokaryotic platforms such as Escherichia coli and eukaryotic systems such as Chinese hamster ovary (CHO) cells or Spodoptera frugiperda 9 (Sf9) insect cells (1, 2). Such heterogeneity poses considerable challenges for downstream process development because purification strategies must be tailored to each product.
To address those challenges and accelerate vaccine availability, Sanofi is pursuing a broadly applicable, platform-based approach to process development. This strategy aims to reduce development timelines, facilitate scale-up, and streamline process transfer into manufacturing facilities. A key element of the platform is a capture step using affinity-tag–based chromatography, which offers high selectivity across diverse protein targets. However, affinity resins present significant limitations: They are relatively expensive and often exhibit limited dynamic binding capacity (DBC) (3). Such constraints can necessitate large column geometries with substantial facility footprints, which may be incompatible with industrial-scale implementation, as well as considerable resin volumes that translate into prohibitive costs.
Related:Using In Silico Modeling To Advance Downstream Process Development
In recent years, multicolumn chromatography (MCC) configurations, in which several columns are interconnected and operated in a coordinated manner, have demonstrated significant potential for enhancing process productivity. Although the approach has been primarily adopted in continuous bioprocessing applications, it is equally relevant for recombinant-protein–based vaccine manufacturing. MCC can improve use of resin binding capacity, thereby reducing required resin volumes and associated buffer consumption (therefore contributing to process sustainability) while ensuring consistent product quality and facilitating scale-up.
MCC operation relies on semicontinuous or continuous purification based on cyclic chromatography, in which at least two columns are connected in series in the loading zone to efficiently capture breakthrough from the first loaded column. Meanwhile, other columns operate in parallel to perform the remaining chromatography phases: wash, elution, cleaning, conditioning, and so on (4). Flow paths switch cyclically, such that each column progresses through the sequence of steps, ultimately leading to steady-state operation after an initial ramp-up phase. Figure 1 depicts the principle of MCC operation.

Figure 1: Principle of multicolumn affinity chromatography; (a) illustrative product breakthrough curve at the column outlet of the column; (b) illustrative profiles inside the columns; (c) example of implementation of a process with three columns, two in the loading zone and one in the elution zone; * = elution includes wash, regeneration, and reequilibration operations.
Despite such advantages, MCC development can be experimentally intensive, requiring numerous trials that consume substantial quantities of product to reach steady-state conditions and to identify optimal operating parameters. Those include the number of columns in the loading zone, the percentage of breakthrough at the first column in the loading zone before column switching (linked to the loading ratio), loading flow rate (i.e., residence time), column geometry, and the number of cycles required to process a defined amount of product, as well as classical chromatography parameters such as step volumes, buffer composition, and gradient or isocratic elution conditions.
Mechanistic modeling of chromatography steps offers an efficient solution to accelerate MCC process development while significantly reducing both the experimental burden and product requirements (5, 6). By accurately predicting chromatographic behavior under a range of operating conditions, mechanistic models enable rapid in silico screening of process parameters, thereby streamlining the path from concept to implementation. In silico approaches enable selection of the most appropriate MCC parameters based on predefined objectives (e.g., yield, cost, and process duration) before performing confirmatory MCC experiments at laboratory or bench scale.
This study demonstrates the application of mechanistic modeling to support development of an MCC affinity capture step for recombinant-protein–based vaccine production, illustrating how such an approach can facilitate and derisk the implementation of a broadly applicable platform process-development strategy.
Materials and Methods
Materials: The target product is a multimeric recombinant protein expressed in CHO cells. The product is clarified before injection on a chromatography system.
Applied buffer solutions included
20 mM tris(hydroxymethyl)aminomethane (tris) (pH 7)
20 mM tris, 150 mM NaCl (pH 7)
20 mM tris, 1 M NaCl (pH7)
20 mM tris, 4 M NaCl (pH 7)
20 mM tris, 1.5 M MgCl2 (pH 7)
20 mM tris, 2 M MgCl2 (pH 7)
0.5 M citric acid
20% ethanol.
Single-column experiments were performed on an Äkta Pure 25 chromatography system from Cytiva, and a BioSMB PD system from Sartorius was used to perform MCC experiments. At laboratory scale, 5-mL prepacked columns (diameter = 0.8 cm, bed height = 10 cm) were used. Pilot-scale experiments leveraged 43.5-mL of resin packed in HiScale columns from Cytiva (diameter = 2.6 cm, bed height = 8.2 cm).
Linear-Gradient Elution (LGE) Experiments: These experiments used 5-mL prepacked columns. For each condition, 2 mL of purified product dialyzed against equilibration buffer was injected. Table 1 details operating conditions for the LGE experiments.

Table 1: Operating conditions for the linear-gradient elution (LGE) experiments; CV = column volume, LGE = linear-gradient elution
Breakthrough Experiment: The breakthrough experiment was performed using a 5-mL prepacked column. Clarified harvest was loaded at a flow rate of 100 cm/h. During injection, flowthrough was collected in 2-mL fractions. Product was loaded until the ultraviolet (UV) signal of the flowthrough was equal to that of the clarified harvest.
Single-Column Purification Experiments: Single-column experiments were performed using 5-mL prepacked columns. The optimal loading ratio was determined to be 4.8 column volumes (CV) of clarified harvest at a residence time of 5 minutes (120 cm/h). The single-column chromatography method was optimized thanks to the modeling of this step. The optimized method is described in Table 2.

Table 2: Description of the optimized single-column process; CV = column volume
Multicolumn Purification Experiments: MCC experiments were performed using a BioSMB chromatography system from Sartorius. A three-column configuration, with two columns in the loading zone, was used for all experiments. Details of the method are provided in Table 3.

Table 3: Multicolumn-chromatography method; the scale-up volume listed (10 L) corresponds to the amount of crude solution processed. (CV = column volume)
Loading velocities at laboratory and pilot scales varied due to differences in column-bed heights between the two scales. To maintain identical residence time across all chromatography steps, and thus comparable step durations, velocities were adjusted accordingly.
At laboratory scale, the product feed concentration was 0.55 g/L, and three cycles were performed. An initial equilibration phase served to equilibrate all three columns simultaneously. Then, a shutdown phase was performed using a standard operation cycle in which the clarified harvest injection was replaced by a pause.
At pilot scale, the product feed concentration was 0.50 g/L, and 11 cycles were performed. An initial equilibration phase served to balance all three columns at the same time. A shutdown phase was performed using the same approach as at laboratory scale, consisting of a standard operation cycle in which the clarified harvest injection was replaced by a pause.
Mechanistic Model
Model Description: Mechanistic models for chromatography are built on three fundamental pillars (7, 8):
thermodynamics, which describes how species behave in a solution and how they interact with a chromatographic medium at equilibrium
hydrodynamics, which describes how fluid flows through a column
kinetics, which describes how rapidly species diffuse from a solution to a chromatographic medium and the other way around.
Thermodynamics acts as the “engine” driving the separation, whereas hydrodynamics and kinetics serve as two “brakes” that degrade separation performance due to peak broadening.
Solution Equilibria: Acid–base dissociation equilibria were accounted for to allow proper calculation of pH and conductivity signals. For simple molecules such as those found in buffer solutions (e.g., tris), each protonation state is considered as an individual species, and acid–base equilibria are described using their associated dissociation constant (pKa) values. For instance, tris+ ⇄ tris + H+ with a pKa of 8.1. For complex molecules such as proteins, a single species is considered, with a net charge that varies as a function of pH. Dissociation equilibria are defined for each amino-acid residue together with their associated pKa values (9). Based on that information, it is possible to calculate, at any given pH, the total number of negative charges, the total number of positive charges, and the net charge (i.e., the sum of negative and positive charges).
Adsorption Isotherm: Because this study focuses on highly specific affinity chromatography, it was assumed that only proteins bearing the affinity tag would interact with the chromatographic medium while all impurities would elute in the liquid phase without interacting with the solid phase. Based on those assumptions, a classical noncompetitive Langmuir adsorption isotherm was selected:
Equation 1:

where C̅j and Cj are the concentrations of protein in the solid and liquid phases, respectively. The term λ̅j represents the linear contribution of the isotherm, N̅ is the adsorbent capacity, and K̅j is the affinity parameter, whose value depends on the magnesium chloride concentration [Mg2+]. The following equation was used:
Equation 2:

where n, K̃Mg2+, and K̃0,j are model-fitting parameters.
Hydrodynamics: Column hydrodynamics were described using a cascade of mixing cells in series. The key model parameter is J, which represents the number of mixing cells.
Kinetics of Mass Transfer: Mass-transfer kinetics were described with the linear driving force approximation. For simple species, a constant characteristic internal mass transfer time (ti) was used. Proteins required an expression depending on the retention strength:
Equation 3:

where ti,0 is a fitting parameter and n is the parameter used in the adsorption isotherm.
External mass transfer (te) was described using the Wakao–Funazkri correlation:
Equation 4:

where Re and Sc are the Reynolds and Schmitt numbers, respectively.
All simulations were performed with Ypso-Ionic software (Ypso-Facto).
Determination of Model Parameters: Model parameters were determined using a methodology described previously (10, 11). Briefly, LGE experiments were performed to estimate the model parameters of the adsorption isotherm, with the exception of the adsorbent capacity, which was determined from a breakthrough curve. Parameters related to the kinetics of mass transfer were initially estimated from the breakthrough curve and subsequently refined using an MCC experiment conducted at 7 CV loading.
Results
Process Description: Switching from a batch process to an MCC approach required several adjustments. The first critical bottleneck identified was an imbalance between the duration of the nonloading steps and that for the loading step. Therefore, a study was conducted to evaluate the feasibility of eliminating resin cleaning between consecutive cycles. This study demonstrated that, even without resin regeneration between cycles, product quality still met specifications, and resin lifetime was not adversely affected.
To further improve the time balance between loading and nonloading steps, the flow rate and volume of each step were optimized. First, the mechanistic model was applied to predict optimal conditions; then, those conditions were confirmed experimentally.
The final step toward establishing a functional MCC method was determination of the loading volume. The availability of a second column in the loading zone enables higher loading volumes than is possible in batch operation. To determine the optimal volume, model-based yield predictions were generated as a function of loading volume and flow rate. Based on those predictions, experimental trials were performed, confirming an optimal loading volume of 7 CV under the conditions investigated. Figure 2 presents a schematic representation of the selected MCC method.

Figure 2: Selected sequence of operations for the three-column process
Process Understanding: Simulation provides access to information that is not easily obtainable experimentally. That is, for instance, the case for detailed outlet concentration profiles, which can be ascertained in silico at each column’s outlet and inlet, within the collection tank, and even in the drain (e.g., waste tank). In contrast, experimental measurements are typically limited to ultraviolet (UV) signals recorded at a few specific locations.
Simulations also provide access to internal concentration profiles, the visualization of which enhances process understanding. One illustrative application is the study of system ramp-up, during which an MCC process progressively reaches a steady state. Figure 3a shows the product concentration at the outlet of the first column in the reference BioSMB run with three columns (7 CV loading) receiving identical injections. Figure 3b shows the corresponding internal concentration profiles. Note that the resin contains less bound product at the end of cycle 1 than at the end of subsequent cycles, indicating that a few cycles are required to reach steady state.
A strategy to accelerate the achievement of steady state and increase productivity consists of applying a power-feed approach, in which a larger amount of product is loaded during the first injection than during subsequent injections. The corresponding results are presented in Figures 3c and 3d, where the injection volume of the first cycle is doubled. Under those conditions, steady state is reached immediately.

Figure 3: Simulated impact of the power-feed strategy to reach steady-state operation; (a) product concentration at the outlet of the first column in the reference case; (b) internal concentration profiles in the reference case; (c) product concentration at the outlet of the first column in the power-feed case; (d) internal concentration profiles in the power-feed case
Process Optimization: Simulation was used to predict the impact of two critical process parameters (CPPs) — namely, loading volume and loading velocity — on three key performance indicators (KPIs) — yield, productivity, and eluent consumption — for a three-column configuration at laboratory scale. KPIs were defined as follows:
Equation 5:

Equation 6:

Equation 7:

where C is the product concentration (in the eluate or feed), m is the mass (of product in the eluate or of product in the feed), ncol. is the number of columns, trun is the process run time, V is volume (of feed, eluate, or process water), Vcol. is the volume of one column, and Vtot.col. is the total volume of the columns (Vcol. × ncol.).
Figure 4 presents simulation results with surfaces. Experimental data are shown as black dots, and the corresponding raw data are provided in Table 4. The simulation shows good agreement with the experimental results. Simulation can therefore be used to screen many operating conditions rapidly and to identify those with the most promising performance.

Figure 4: Impact of loading volume and velocity on yield, productivity, and eluent consumption; black dots correspond to experimental results. (CV = column volume)

Table 4: Overview of experimental runs performed at laboratory scale with the BioSMB chromatography system; CV = column volume
The highest yields were obtained at low loading velocity and low loading volume because those conditions minimized product loss during the loading phase. However, low loading velocities are associated with reduced productivity. Therefore, a trade-off must be identified to achieve high yield alongside reasonable productivity. Eluent consumption increases with faster velocities due to greater product losses. It also decreases with higher loading volumes because a larger amount of product is processed per cycle, even though yield (as a percentage) may decrease.
Defining a cost function allows consideration of multiple KPIs at once and thus eases process selection. In this study, the following cost function was used:
Equation 8:

where time refers to process time, a quantifies the feed cost (€/g of product), b represents the resin cost (€/L resin), c is the raw-material cost (€/L of eluent), and d equals the labor cost (€/hour). For those parameters, illustrative values were considered to demonstrate the impact of loading volume and velocity on cost.
Figure 5 shows the cost results as a function of the loading volume and loading velocity.

Figure 5: Impact of loading volume and velocity on cost; CV = column volume
Process Scale-Up: Once a mechanistic chromatographic model is developed at laboratory scale, it can be used to predict process performance at other scales. This capability can be useful, for instance, to
verify in advance that an operating recipe considered for large-scale implementation is appropriate, thereby reducing the number of large-scale runs
understand and interpret potential discrepancies between predicted and experimental results, thus supporting decision-making for corrective actions.
Such an approach is illustrated in Figure 6, where the BioSMB process operated at 7 CV loading was scaled up to process 10 L of clarified harvest. Three columns were used in the system. UV signals from the experiments nicely overlapped with the simulated concentration profiles for both for the collection tanks (Figure 6a) and drain (Figure 6b). Because the UV signal measured in the drain was saturated, a detailed comparison between experiment and simulation was not possible for this stream. Experimental and simulated yields were 85.6% and 86.6%, respectively, demonstrating the good predictive capability of the model.

Figure 6: Experimental (EXP) and simulated (SIM) values for the three-column BioSMB run with 7 column volumes (CV) loading at the 10-L scale; (a) product and impurity concentrations at the inlet of the collection tank; (b) product and impurity concentrations in the drain. (UV = ultraviolet light)
Discussion
Interest of an MCC Approach: This section presents an application example with the following objectives:
a yield above 85%
15 cycles per column, corresponding to the expected resin lifetime
processing of 200 L of clarified harvest to generate drug substance for use in clinical trials.
According to Figure 4, the operating conditions that enable a yield above 85% while maximizing productivity (which is the main cost driver because it directly reflects the total CVs required) are a loading volume of 6.5 CV and a loading velocity of 180 cm/h.
The required total column volume (VTot.col.) can be estimated as follows for both single-column and multicolumn systems:
Equation 9:

where Vfeed is the volume of feed to be processed, Cfeed is the product concentration in the feed, Ncycles is the number of cycles required to process the feed volume, capacity is the static capacity of the chromatographic medium, and margin corresponds to the fraction of the resin that is effectively used. The closer that value is to unity, the more efficiently a resin is being used. In a multicolumn system, columns connected in series during the loading phase allow capture of breakthrough product, resulting in a higher margin compared with a single-column system.
Table 5 presents results for both the single-column and MCC configurations, considering a Cfeed value of 0.55 g of product/L of resin and a resin capacity of 3.4 g of product/L of column. For the single-column process, two scenarios were evaluated: a single injection of feed solution (single pass) and two consecutive injections of feed solutions (double pass). We found that the multicolumn process enables close to a 20× reduction in total column volume compared with the classical single-column, single-pass process. A 10-fold reduction in column volume was achieved relative to the double-pass single-column process.

Table 5: Column sizing for the single-column and multicolumn process
Interest of Mechanistic Modeling Approach: MCC development requires substantial quantities of product as well as considerable development time. Indeed, for each experimental condition, several cycles must be performed to reach steady-state conditions. With a mechanistic modeling approach, computational experiments can be conducted, and only the most promising operating conditions need to be tested experimentally, substantially reducing laboratory effort and material consumption.
Selection of an optimal loading ratio and flow rate provides a clear illustration of the benefit. In the absence of a mechanistic model, a design of experiments (DoE) approach would typically be applied. Using a response-surface design with two center points (one of the simplest designs), 10 experiments would be required to explore the design space. In contrast, using a mechanistic model allows identification of three experiments that would be sufficient to select the appropriate operating parameters. In the data presented here, four experiments were conducted, with the additional condition (10-CV loading) used solely for model validation. Considering that ≈400 mL of product is required per experiment, a DoE-based approach would therefore require three times more material than would the mechanistic modeling strategy.
Beyond experimental efficiency, a mechanistic approach also represents a powerful tool for securing scale-up because it supports rational column-geometry selection and enables verification that selected flow rates will not exceed pressure-drop limitations.
Conclusion
This study demonstrates that mechanistic modeling represents a powerful, efficient, and reliable approach for MCC process development. Our findings also show that a mechanistic model for an MCC process can be readily derived from an existing batch chromatography model, providing a robust foundation for process understanding and optimization.
The established model proved to be accurate and predictive, as evidenced by the close agreement between experimental results and model simulations across different scales. That validation confirms the robustness and applicability of mechanistic modeling for MCC process development and scale-up.
Compared with conventional statistical DoE approaches, mechanistic modeling offers several distinct advantages for MCC development:
enhanced process understanding — a mechanistic framework provides deeper insight into underlying physical and chemical phenomena, enabling more informed and rational decision-making
improved process efficiency — for example, the model supports faster achievement of steady-state conditions and enables global process optimization across operating parameters
system-independent process definition — process characterization can be performed independently of a specific chromatography system, requiring only limited adjustment of system specific parameters (e.g., dead volumes)
optimal parameter determination — key operating parameters (e.g., loading volume and flow rate) can be optimized according to defined objectives (productivity, process duration, and yield), allowing rapid comparison of multiple scenarios to identify optimal trade-offs (e.g., yield versus productivity)
significant reduction in experimental effort — a mechanistic approach requires approximately threefold fewer experiments than do standard DoE strategies, substantially reducing resource consumption and development timelines
streamlined scale-up — the model accurately predicts process behavior across scales, reducing risk and experimental burden during scale-up activities.
Overall, implementation of mechanistic modeling for MCC process development provides capabilities that cannot be achieved by experimental approaches alone, including reduced experimental effort, enhanced process knowledge, and the ability to evaluate alternative process strategies in silico. Consequently, mechanistic modeling represents a key enabling element for the design of efficient, scalable, and robust MCC processes, supporting the successful achievement of development and manufacturing objectives in biopharmaceutical manufacturing.
Funding Statement
This work was funded by Sanofi. Part of it was performed by Ypso-Facto in the form of consulting services to Sanofi.
Disclosure of Interests
Eric Forma and Alan Deduyer are Sanofi employees and may hold shares and/or stock options in the company.
Acknowledgments
The authors express their gratitude to Jean-Sébastien Bolduc, Cédric Charretier, and Guillaume Jeanne from Sanofi for their critical review of this manuscript and to members of the Sanofi Vaccine Drug Substance Development team who contributed to this work.
References
1 Cid R, Bolívar J. Platforms for Production of Protein-Based Vaccines: From Classical to Next-Generation Strategies. Biomolecules 11(8) 2021: 1072; https://doi.org/10.3390/biom11081072.
2 Sookhoo JRV, et al. Protein Expression Platforms and the Challenges of Viral Antigen Production. Vaccines 12(12) 2024: 1344; https://doi.org/10.3390/vaccines12121344.
3 Zhao M, et al. Affinity Chromatography for Vaccines Manufacturing: Finally Ready for Prime Time? Vaccine 37(36) 2019: 5491–5503; https://doi.org/10.1016/j.vaccine.2018.02.090.
4 Silva RJS, et al. Improving the Downstream Processing of Vaccine and Gene Therapy Vectors with Continuous Chromatography. Pharm. Bioprocess. 3(8) 2015: 489–505.
5 Baur D, et al. Optimal Model-Based Design of the Twin-Column CaptureSMB Process Improves Capacity Utilization and Productivity in Protein A Affinity Capture. Biotechnol. J. 11(1) 2016: 135–145; https://doi.org/10.1002/biot.201500223.
6 Baur D, et al. Model-Assisted Process Characterization and Validation for a Continuous Two-Column Protein A Capture Process. Biotechnol. Bioeng. 116(1) 2019: 87–98; https://doi.org/10.1002/bit.26849.
7 Pfister D, Nicoud L, Morbidelli M. Continuous Biopharmaceutical Processes: Chromatography, Bioconjugation, and Protein Stability. Cambridge University Press: Cambridge, UK, 2018; https://doi.org/10.1017/9781108332897.
8 Nicoud R-M. Chromatographic Processes: Modeling, Simulation, and Design. Cambridge University Press: Cambridge, UK, 2015; https://doi.org/10.1017/CBO9781139998284.
9 Dean JA. Lange’s Handbook of Chemistry (15th edition). McGraw-Hill: New York, NY, 1998.
10 Kobl K, et al. Oligonucleotide Purification by Ion Exchange Chromatography: A Step-by-Step Guide to Process Understanding, Modeling, and Simulation. Org. Process Res. Dev. 28(7) 2024: 2569–2589; https://doi.org/10.1021/acs.oprd.4c00013.
11 Pfister D, et al. Purification of a Viral Protein by Ion-Exchange Chromatography: Methodology for Mechanistic Modeling and Comparison with a Statistical Approach. BioProcess Int. 23(9) 2025: 24–31; https://www.bioprocessintl.com/chromatography/purification-of-a-viral-protein-by-ion-exchange-chromatography-methodology-for-mechanistic-modeling-and-comparison-with-a-statistical-approach.
Alan Deduyer is a downstream scientist ([email protected]); Eric Forma is a downstream principal scientist ([email protected]); and Marseille Polytechnical University student Estelle Guiot was an intern, all in vaccine CMC development and supply at Sanofi, 1541, avenue Marcel Mérieux – 69280 – Marcy l’Étoil, France; https://sanofi.com. Lucrèce Nicoud is cochief executive officer, and David Pfister is head of research and development ([email protected]), both at Ypso-Facto 19 Avenue Foch 54000 Nancy, France; https://www.ypsofacto.com.
Please cite this article as Deduyer A, et al. Simulation-Aided Development of Multicolumn Chromatography Processes for Protein-Based Vaccine Production. BioProcess Int. 24(9) 2026: 240906.
来源:BioProcess International · 工艺与质量 · bioprocessintl.com