美国FDA对一家印度固体制剂生产商发出警告信,指其片剂投诉调查、非专用设备清洁和清洁验证存在严重缺陷。2025年8月检查中,至少两个批次的片剂因易碎多孔被投诉,偏差调查以未确认结案并归因于某原料固有性质,FDA认为后续答复缺少留样分析与消除措施。检查还发现通风管道和胶囊灌装机残留的多种活性成分超过企业自定限值,企业已同意暂停该厂区生产与放行,完成整改并再次告知FDA后方可恢复对美生产。

推荐理由

材料归纳了FDA警告信中片剂投诉调查、共用设备清洁与清洁验证的具体缺陷,呈现投诉调查与清洁程序的常见薄弱环节。

正文 · 原文

Back in August 2025, the US FDA inspected an Indian manufacturer of solid dosage forms and identified serious GMP deficiencies. The complaints relate in particular to inadequate investigations of quality defects in tablets, deficiencies in the cleaning of non-dedicated equipment and deficiencies in the cleaning validation programme. Due to these violations, the FDA classifies the manufactured medicinal products as non-GMP-compliant.Complaint handling / CAPAOne key point of criticism concerns the handling of quality defects in tablets. The FDA objects that customer complaints about tablets with physical defects were not properly investigated. Specifically, there were complaints about tablets from at least two different batches that were described as crumbly and holey, with powder/dust in the container. The deviation investigations carried out by the manufacturer were unable to determine a reliable cause and were concluded with the result 'not confirmed'. In the investigation reports, the manufacturer stated that the occurrence of crumbly/pitted tablets was due to the 'inherent nature' of a raw material used. At the same time, the manufacturer documented that there were further complaints about the same defect pattern from three other batches of the same medicinal product.Although the manufacturer reopened the deviation investigation after the inspection and has now attributed the cause to the aforementioned raw material, the FDA considers the response to be insufficient. According to the FDA, there is no analytical testing of the retained samples to prove that the affected batches still meet the specifications. Neither a chemical analysis nor a test of dissolution or other quality-related parameters has been documented or promised. In addition, measures to eliminate the identified cause, such as adjustments to the formulation, are lacking. Furthermore, no assessment has been made as to whether other medicinal products containing the same raw material could also be affected by comparable quality defects.Deficiencies in cleaning and cleaning validationIn addition to deficiencies in complaint/CAPA processing, the FDA identified significant deficiencies in the cleaning and maintenance of non-dedicated equipment. During the inspection, visible contamination was observed in ventilation ducts and residues on a capsule filling machine, even though these systems were documented as having been cleaned and product changes had already been carried out. Analytical investigations of these contaminants revealed the presence of several active ingredients in concentrations above the company's own limits. In the FDA's view, this poses a concrete risk of cross-contamination.Although the manufacturer carried out investigations and reviewed analytical and stability data for previously manufactured products, it cited gaps in the cleaning instructions as the sole cause. The FDA considers this insufficient, as it has not been proven that products already released are free of cross-contamination. In particular, there is a lack of investigations of retained samples from batches intended for the US market and manufactured on the affected equipment.In addition, the FDA criticises fundamental deficiencies in the cleaning validation programme. The cleaning validation from 2018 did not take into account the worst-case product identified in each case and is therefore not suitable for ensuring the effectiveness of cleaning in shared facilities, according to the FDA. In addition, the cleaning validation concept was not updated when new products were introduced on the same equipment. There is also no routine cleaning verification. As a consequence of the deficiencies identified, the manufacturer has agreed to temporarily suspend the manufacture and release of medicinal products at this site. Production for the US market can only be resumed once the deficiencies identified have been completely rectified and the FDA has been informed again.Please see the FDA website to read the Warning Letter in detail.

来源:ECA GMP News · gmp-compliance.org