FDA OPQ 发布 MAPP 5015.5 Rev. 1:包装材料 III 型 DMF 的 CMC 审评政策
MAPP 5015.5 Rev. 1 CMC Reviews of Type III DMFs for Packaging Materials
美国 FDA 药品质量办公室(OPQ)发布 MAPP 5015.5 Rev. 1,规范包装材料 III 型 DMF 中 CMC 信息的审评,明确何时应撰写书面审评及如何判定 DMF 与所支持申请是否满足包装系统安全性评估要求。该文件生效日期为 2022 年 12 月 9 日,此前版本生效日期包括 2010 年 3 月 22 日、2011 年 8 月 12 日及 2017 年 10 月 18 日。
PDF 文字版;图形和原始排版请参阅官方 PDF。
第 1 页
MANUAL OF POLICIES AND PROCEDURES
CENTER FOR DRUG EVALUATION AND RESEARCH MAPP 5015.5 Rev. 1
POLICY AND PROCEDURES
OFFICE OF PHARMACEUTICAL QUALITY
CMC Reviews of Type III DMFs for Packaging Materials
Table of Contents
PURPOSE ..............................................................................1
BACKGROUND ...................................................................1
POLICY .................................................................................3
RESPONSIBILITIES AND PROCEDURES .....................6
REFERENCES......................................................................7
EFFECTIVE DATE ..............................................................8
CHANGE CONTROL TABLE............................................8
PURPOSE
• This MAPP establishes standardized policy within the Office of Pharmaceutical
Quality (OPQ) for chemistry, manufacturing, and controls (CMC) review of
information regarding certain packaging materials in type III drug master files
(DMFs). Specifically, this MAPP addresses when a written review of a Type III
DMF should be prepared and how a reviewer should determine whether the
information in the DMF and the application it supports satisfies the requirements
for assessing the safety assessment of certain packaging systems intended for use
with drug substances and orally and parenterally administered drug products.
BACKGROUND
• Reviewing the packaging information in a new drug application, an abbreviated
new drug application, a biologics license application, an investigational new drug
application, or an amendment or supplement to these applications involves
assessing whether each packaging component or material is suitable for its
intended use. Suitability is generally assessed in terms of protection,
compatibility, safety, and performance (as described in more detail in section
III.C of the guidance for industry, Container Closure Systems for Packaging
Human Drugs and Biologics: Chemistry, Manufacturing, and Controls
Documentation.
Originating Office: Office of Pharmaceutical Quality
Effective Date: 3/22/10, 8/12/11; 10/18/2017; 12/9/2022 Page 1 of 8
第 2 页
MANUAL OF POLICIES AND PROCEDURES
CENTER FOR DRUG EVALUATION AND RESEARCH MAPP 5015.5 Rev. 1
• Suitability information for packaging components or materials may be submitted
either in the application or a referenced DMF. However, the following
information is typically provided in a type III DMF:
o Description of the packaging component or material (e.g., high density
polyethylene (HDPE) bottles, polypropylene (PP) caps) or description of a
material of construction (MOC) (e.g., HDPE resin, PP resin).
o Quantitative or qualitative statement of the composition.
o Release specification or quality attributes for the packaging component or
material.
o Results of certain kinds of qualification testing (e.g., some of the tests
described in United States Pharmacopeia (USP) General Chapter <661>).
• The following information is usually provided in the application:
o Information that addresses a container closure system’s protection,
compatibility, and performance attributes.
o Fundamental or basic physical attributes (e.g., component dimensions). (These
attributes are usually addressed in the applicant’s acceptance specifications.)
• Assessment of the safety of a packaging component or material is generally based
on the potential or observed interaction between the MOC and the drug substance
or drug product during storage and usage. Reviewers should consider the
following factors when evaluating the safety of packaging components or
materials:
o Drug product’s dosage form and route of administration.
o MOCs of the packaging components and materials.
o Likelihood that a component of the MOC will leach into the drug substance or
drug product. (Unless a component in an MOC is volatile, a medium of
extraction (e.g., a liquid phase) must usually be present for leaching to occur.)
o Amount of leachable materials detected in the drug substance or drug product.
o Toxicity of the leachable material, taking into account the dosage form, route
of administration, target population, and patient exposure.
o Usually, if water and ethanol are the only potential extraction media, the
safety of the MOC can be established by referencing appropriate food additive
Originating Office: Office of Pharmaceutical Quality
Effective Date: 3/22/10, 8/12/11; 10/18/2017; 12/9/2022 Page 2 of 8
第 3 页
MANUAL OF POLICIES AND PROCEDURES
CENTER FOR DRUG EVALUATION AND RESEARCH MAPP 5015.5 Rev. 1
regulations (FARs) under 21 CFR 172-186 and the cited uses for the listed
materials. Some MOCs listed in the FARs are specifically designated as being
acceptable for use with fatty foods (see 21 CFR 177.1330(d)(1)). If leachable
material is a cause for concern, it may be appropriate to review the applicable
DMF to assess the details of its composition.
• Typically, the supplier of the packaging component or material provides the
composition information, and the applicant provides the remaining safety
information (including the list of leachable materials). (Refer to relevant USP
monographs, as well as USP extraction tests on plastics (USP General Chapter
<661>) and USP Biological Reactivity Tests (USP General Chapters <87> and
<88>) on plastics).
POLICY
Written Review of Information in a Type III DMF
• Written review of the information in a type III DMF should be prepared
unless the information in the application sufficiently establishes that the
packaging material or component is suitable for its intended use. The table on
page 5 outlines the appropriate CMC information and FAR citations that may
be referenced to satisfy this requirement for information.
• Other circumstances under which a DMF might not need review (e.g., the
item has been reviewed previously for a similar drug product) are outside the
scope of this MAPP.
• The status of each type III DMF referenced in the application should be
indicated in the CMC review of that application.
Decision Process to Determine Whether Information in the Application is
Adequate
• The table below lists the dosage forms, routes of administration, and MOCs
that this MAPP addresses and summarizes the information typically accepted
to support the safety assessment of the MOCs used in the packaging
component. A particular drug product and container closure configuration
must satisfy all three of these criteria to be covered by this MAPP. For
example, a rubber stopper used for a parenteral solution is not covered by this
MAPP. Bulk drug substances are included under the heading “Dosage Form.”
Notes follow the table and provide more specific information.
Originating Office: Office of Pharmaceutical Quality
Effective Date: 3/22/10, 8/12/11; 10/18/2017; 12/9/2022 Page 3 of 8
第 4 页
MANUAL OF POLICIES AND PROCEDURES
CENTER FOR DRUG EVALUATION AND RESEARCH MAPP 5015.5 Rev. 1
Dosage Route of Medium of Container Component MOC Expected Safety
Form Admini- Extraction Closure Information
stration
Drug N/A None Bag Bag Polymer1 FAR Citation2
Substance, Bottle Bottle1 Glass USP Glass3
Powder Polymer1 FAR Citation2
Cap1 Polymer1 FAR Citation2
Non- Composition
Polymer4
Liner5 Polymer1 FAR Citation2
Adhesive6 FAR Citation2
Inner Seal5 Polymer1 FAR Citation2
Adhesive6 FAR Citation2
Tablet, Oral None Bottle Bottle1 Glass USP Glass3
Capsule Polymer1 FAR Citation2
(including Cap1 Polymer1 USP Plastics7
liquid- Liner5 Polymer1 FAR Citation2
filled soft Adhesive6 FAR Citation2
gelatin) Inner Seal5 Polymer1 FAR Citation2
Adhesive6 FAR Citation2
Desiccant Ink, FAR Citation2
and Oxygen Container,
Scavengers8 Sorbent
Pharma- Rayon or USP Monographs
ceutical Cotton for Purified Cotton
Coil9 and Purified Rayon
Blister10 Laminate11 Polymer1 FAR Citation2
Sachet Adhesive6 FAR Citation2
Solution, Oral Aqueous Bottle Bottle1 Glass USP Glass3
Suspension Vehicle12 Polymer1 FAR Citation2
Cap1 Polymer1 USP Plastics7
Liner5 Polymer1 FAR Citation2
Adhesive6 FAR Citation2
Inner Seal5 Polymer1 FAR Citation2
Adhesive6 FAR Citation2
Dropper14 Glass USP Glass3
Polymer1 FAR Citation2
Solution for Parenteral Aqueous Ampoule, Ampoule, Glass USP Glass3
Injection Vehicle12 Vial, Vial,
Powder for None Syringe13 Syringe13
Injection Barrel
Originating Office: Office of Pharmaceutical Quality
Effective Date: 3/22/10, 8/12/11; 10/18/2017; 12/9/2022 Page 4 of 8
第 5 页
MANUAL OF POLICIES AND PROCEDURES
CENTER FOR DRUG EVALUATION AND RESEARCH MAPP 5015.5 Rev. 1
NOTES
1. Polymers: Bags used for drug substances and bottles and caps used for both drug
substances and drug products are usually manufactured with polyethylene or
polypropylene resins, whose constituents are FAR listed (see note 2). If the drug
substance or drug product contains a residual solvent that may act as a medium of
extraction, then potential extractables should be taken into consideration.
2. FAR Citation: Food additive regulations (21 CFR 172-186); many contain
approved uses and limits for particular additives.
3. USP Glass: USP General Chapter <660> Containers – Glass.
4. Non-Polymer Caps: A drug substance or drug product may be packaged in bottles
with metal caps. The cap is not considered to interact with the contents and requires
no qualification information.
5. Liners and Inner Seals: These are usually laminates (see note 11).
6. Adhesives: These are a class of polymers (usually polymethacrylates) and may be
part of a laminate (see note 11) or applied separately.
7. USP Plastics: USP General Chapter <661>, Containers – Plastics.
8. Sorbents: These are desiccants and oxygen absorbers. Typically they are packaged
in paper or plastic containers that are reviewed for safety only. Issues of
performance in terms of oxygen or moisture absorption are generally included in
the review of the application that the DMF supports. Sorbent containers may also be
printed with ink. The MOCs for the desiccant, oxygen absorber, container, and
printing ink should comply with the cited FARs if they are in contact with the drug
substance or product.
9. Pharmaceutical Coil: If this material has been bleached, it should be shown to be
free of residual bleaching agents (usually peroxides). The coil’s moisture content
may be an issue if the drug product is moisture sensitive.
10. Blister: A blister is composed of two films (usually laminates) that are sealed
together to contain the drug product. The two films may be the same or different.
11. Laminates: These consist of layers of polymer, paper, foil, and/or adhesive. One or
more of the layers usually forms a “functional barrier” (see note 15) between the
contents and the exterior (atmospheric air or other components). All materials
between the functional barrier and container contents are expected to comply with
appropriate FARs. Films made of polyvinyl chloride (PVC) should have a residual
vinyl chloride monomer content of <5 parts per billion.
Originating Office: Office of Pharmaceutical Quality
Effective Date: 3/22/10, 8/12/11; 10/18/2017; 12/9/2022 Page 5 of 8
第 6 页
MANUAL OF POLICIES AND PROCEDURES
CENTER FOR DRUG EVALUATION AND RESEARCH MAPP 5015.5 Rev. 1
12. Aqueous: Water is the primary vehicle. It may contain co-solvents and other
excipients that may affect the extraction properties (e.g., significant amounts of an
alcohol or surfactant). The CMC reviewer will evaluate the potential for extraction
by the medium and review the composition of the MOC in the DMF, if necessary.
13. Ampoule, Vial, Syringe: If pre-sterilized or pre-treated (e.g., with silicone), then
processing for sterilization or coating may require review.
14. Dropper: A CMC reviewer will evaluate other MOCs used for a dropper assembly
(e.g., ink, rubber bulb) on a case-by-case basis.
15. Functional Barrier: FDA’s Center for Food Safety and Applied Nutrition (CFSAN)
has accepted the concept of “functional barrier” as a subset of the “no migration”
exclusion in the definition of food additive (21 CFR 170.3(e)). An exception to the
requirement for assessing the migration of materials used in food packaging is made
when there is a determination that the material is not reasonably expected to migrate
to the food above the “threshold of regulation” (21 CFR 170.39), or at least not
above a safe limit based on the toxicity of the material in question. If the food
contact materials are determined to form a layer that prevents the migration of
materials from the outer layers, then a functional barrier is presumed to exist and
materials outside the functional barrier are presumed to be unable to migrate into
the food. Safety of the materials in the outer layers requires less scrutiny.
No formal definition for functional barrier exists in the Federal Food, Drug, and
Cosmetic Act or in FDA regulations. The concept, however, is addressed in CFSAN
guidances regarding recycled plastics and premarket submission for food contact
substances (see REFERENCES). The term is also cited with reference to packaging
for human foods in 21 CFR 109.30(c), 175.300(a), 176.160(b)(2), and 177.1390(a).
An example of a functional barrier is metal foil or a polymeric material of sufficient
thickness and impermeability. An example of an exterior layer material is printing
ink or adhesive.
RESPONSIBILITIES AND PROCEDURES
Primary CMC Reviewer
• Determines whether the information in the application is adequate to establish
that the packaging component or material is suitable for its intended use.
• If the information is adequate, documents the conclusion and provides a
justification in the review of the application. A DMF review is not necessary.
Originating Office: Office of Pharmaceutical Quality
Effective Date: 3/22/10, 8/12/11; 10/18/2017; 12/9/2022 Page 6 of 8
第 7 页
MANUAL OF POLICIES AND PROCEDURES
CENTER FOR DRUG EVALUATION AND RESEARCH MAPP 5015.5 Rev. 1
• If the information is not adequate, requests additional information from the
applicant through appropriate channels.
• If the applicant does not respond or the information in the response is not
adequate, determines whether the DMF has been previously reviewed and
whether the previous review is applicable to the current drug product.
o If the previous review is applicable to the current drug product, documents
the conclusion from the previous DMF review and provides a justification
in the review of the application that the DMF supports. A DMF review is
not necessary.
o If the previous review is not applicable to the current drug product,
prepares a DMF review.
If the information in the DMF is adequate, documents the conclusion
in the review of the application, as well as in the DMF review.
If the information in the DMF is not adequate:
• Prepares a draft letter to the DMF holder to communicate
comments.
• Documents the conclusion in the application review, as well as in
the DMF review.
Secondary CMC Reviewer
• Signs off on the DMF review.
• Signs off on the CMC review of the application.
REFERENCES
• 21 CFR 314.420, Drug Master Files.
• Guidance for industry, Guideline for Drug Master Files.
• Guidance for industry, Container Closure Systems for Packaging Human Drugs
and Biologics: Chemistry, Manufacturing, And Controls Documentation.
• 21 CFR 172-186 [direct additives, indirect additives, and GRAS materials].
• Guidance for industry, Use of Recycled Plastics in Food Packaging: Chemistry
Considerations.
Originating Office: Office of Pharmaceutical Quality
Effective Date: 3/22/10, 8/12/11; 10/18/2017; 12/9/2022 Page 7 of 8
第 8 页
MANUAL OF POLICIES AND PROCEDURES
CENTER FOR DRUG EVALUATION AND RESEARCH MAPP 5015.5 Rev. 1
• Guidance for industry, Preparation of Premarket Submissions for Food Contact
Substances: Chemistry Recommendations.
EFFECTIVE DATE
This MAPP is effective upon date of publication.
CHANGE CONTROL TABLE
Effective Revision Revisions
Date Number
3/22/2010 Original
8/12/2011 Rev. 1 Under “NOTES,” changed:
#3. “<661>, Chemical Resistance – Glass Containers” to “<660>
Containers – Glass”; and
#7. “Physiochemical Tests – Plastics; Polyethylene Terephthalate
Bottles and Polyethylene Terephthalate G Bottles; and
Polypropylene Containers” to “Containers – Plastics”.
10/18/2017 N/A Administrative changes
12/9/2022 N/A Recertified: no changes
Originating Office: Office of Pharmaceutical Quality
Effective Date: 3/22/10, 8/12/11; 10/18/2017; 12/9/2022 Page 8 of 8