FDA 向荷兰一工厂发出警告信,指其根因调查与 CAPA 不足

Root Cause Investigations criticised at EU Company

AI 导读

FDA 就荷兰一工厂 2024 年 10 月的检查发出警告信,援引 21 CFR 210 与 211,指其未彻底调查批次异常。该厂出现七次微生物含量超限事件,其中至少两次达 10,000 CFU/mL,而企业仅审查事件前后一天的测试结果。FDA 认为企业回复不充分,要求对该调查系统进行独立评估并提交详细整改计划。

正文 · 原文

The US FDA is still conducting GMP inspections in the EU despite the MRA. In October 2024 a facility in the Netherlands was inspected. Now a Warning Letter was issued summarising significant violations of Current Good Manufacturing Practice (21 CFR parts 210 and 211).The first observation written down states that the "firm failed to thoroughly investigate any unexplained discrepancy or failure of a batch or any of its components". What happened?The company experienced seven out-of-limit (OOL) events for microbial content in a system used to generate a major component of drug products. Notably, at least two events showed microbial levels as high as 10,000 colony-forming units (CFU) per milliliter, far exceeding acceptable limits. Despite the severity and frequency of these events, the company's investigations were deemed inadequate. The findings raise concerns about the company's ability to consistently produce components suitable for pharmaceutical use, with particular focus on "root cause determinations, corrective actions and preventive actions (CAPAs), and assessment of all potentially affected batches". Instead, the company limited its response to a narrow review of system test results from the day before and after each OOL event and relied on finished product test results to justify continued production-without demonstrating control over the system itself. In the response to the observations, the company then indicated that "individual investigations with impact assessments will be created" for OOL results. Additionally, it was decided that the "quality lead will review and document results" on a defined basis. Furthermore, the company committed to train the quality team accordingly. However, the FDA rates this response as "inadequate". The authority misses a "comprehensive retrospective risk assessment" and an evaluation of "the full scope and impact of OOL results". Also supporting documentation about the CAPAs was missing.The FDA is now looking for an "independent assessment of the overall system for investigating deviations, discrepancies, complaints, out-of-specification results, and failures" plus a "detailed action plan to remediate this system". The action plan should also include, "significant improvements in investigation competencies, scope determination, root cause evaluation, CAPA effectiveness, quality assurance oversight, and written procedures". This case underscores the importance of a thorough root cause determination and CAPAs, particularly when dealing with repeated events.

来源:ECA GMP News · gmp-compliance.org