FOOD AND DRUG ADMINISTRATION                                                       PROGRAM        7356.002P
COMPLIANCE PROGRAM GUIDANCE MANUAL

                                     CHAPTER 56 - DRUG QUALITY ASSURANCE

SUBJECT:                                                                           IMPLEMENTATION DATE
POSITRON EMISSION TOMOGRAPHY (PET)
CGMP DRUG PROCESS AND PRE-APPROVAL                                                       09/11/2015
INSPECTIONS/INVESTIGATIONS
                                                                                   COMPLETION DATE
Revision Note: Program revised 09/11/2015 to update implementation
date, completion date, organizational/procedural changes and program
contacts.                                                                               09/11/2016

REF: 7356.002 (09/11/2015) and 7346.832 (5/10/2010)

                                                      DATA REPORTING
                  PRODUCT CODES                                        PROGRAM ASSIGNMENT CODES
All PET Drugs                                             56002P Drug Process Inspections (PET)
Industry code: 65
                                                          46832P Positron Emission Tomography (PET) Pre-
Profile Class code: PET                                   Approval Inspections/Investigations (NDA)
                                                          52832P Positron Emission Tomography (PET) Pre-
                                                          Approval Inspections/Investigations (ANDA)



FIELD REPORTING REQUIREMENTS:

Establishment Inspection Reports (EIRs) are to be created and filed electronically using the PET-specific
module in TurboEIR or replacement system that is accessible to both ORA and CDER.
For inspections of routine commercial manufacturing classified as Official Action Indicated (OAI) due to
failure to comply with 21 CFR Part 212 Current Good Manufacturing Practice (CGMP) as they apply to
PET drugs, submit advisory, administrative, or judicial action recommendations via MARCS-CMS in
accordance with the Regulatory Procedures Manual (RPM).
Districts should immediately report significant issues according to current FACTS, Panorama and CMS
procedures. This includes promptly filing and changing OAI notifications.
During an inspection, if you obtain information pertaining to inadequate adverse drug experience (ADE)
reporting, unapproved drug issues, or post-approval reporting violations (application supplements, Field
Alert Reports (FARs), etc.), report in accordance with directions provided in the applicable compliance
programs and under separate captions in the EIR. Data system information about these inspectional
activities should be reported under separate Program Assignment Codes (PACs). Expansion of coverage
under these programs into a CGMP inspection should be reported under this compliance program.
The Districts are requested to use this compliance program for all PET CGMP inspections.




DATE OF ISSUANCE                    09/11/2015                                               COVER - Page 1 of 1
FORM FDA 2438g (electronic-09/2003)

第 2 页

                                                                                     PROGRAM           7356.002P


                                            PART I - BACKGROUND

PET is a medical imaging modality involving the use of a unique type of radiopharmaceutical drug
product that contains a positron emitting isotope. The majority of PET drugs are injected intravenously
into patients for diagnostic purposes. Many PET drugs are produced using cyclotrons and other
production equipment at locations that are close to the patients to whom the drugs are administered (e.g.,
in hospitals or academic institutions). A cyclotron is a type of particle accelerator that accelerates
charged particles using a high frequency, alternating voltage (potential difference) to prepare a specific
radionuclide through a particular nuclear reaction. PET drug production is a related series of processes
and operations that result in the preparation of a PET drug product. Major operations or steps in PET
drug production typically include chemical syntheses, aseptic filling, labeling, and testing. Aseptic
processing and sterility controls within the systems are critical processes and controls for coverage in
the various systems. PET drugs are intended for diagnostic use and are not intended to provide a
therapeutic effect; however, many PET drugs provide their diagnostic effect by binding to receptors,
which is a type of pharmacological activity.

Section 121(c)(1)(A) of the FDA Modernization Act of 1997 (Modernization Act) directed FDA to
establish appropriate approval procedures and CGMP requirements for PET drugs. During the
development of the PET drug CGMP requirements and approval procedures, FDA evaluated and
considered any relevant differences between not-for profit institutions that produce PET drugs for their
patients and commercial manufacturers of PET drugs. FDA also consulted with patient advocacy
groups, professional associations, manufacturers, and physicians and scientists who make or use PET
drugs (as stated under section 121(c)(1)(B) of the Modernization Act). FDA presented the initial
tentative approach to PET drug CGMP requirements and responded to numerous questions and
comments about that approach at a public meeting on February 19, 1999. FDA announced the
availability of preliminary draft regulations on PET drug CGMP requirements in the September 22,
1999 issue of the Federal Register (64 FR 51274). FDA held a public meeting to discuss the
preliminary draft regulations on September 28, 1999. FDA announced the availability of a preliminary
draft proposed rule on PET drug CGMP requirements in the April 1, 2002 issue of the Federal Register
(67 FR 15344). FDA held a public meeting to discuss the preliminary draft proposed rule and draft
guidance on April 21, 2002. FDA also announced the availability of a guidance on ‘‘PET Drug
Products—Current Good Manufacturing Practice (CGMP)” on April 1, 2002 (67 FR 15404). In the
Federal Register of September 20, 2005, FDA published a proposed rule to establish CGMP
requirements for PET drugs.

The Federal Food, Drug, and Cosmetic Act provides that FDA may approve a New Drug Application
(NDA), an Abbreviated New Drug Application (ANDA), and a Biologic Licensing Application (BLA)
if, among other requirements, the methods used in, and the facilities and controls used for, the
manufacture, processing, packing, and testing of the drug are found adequate, and ensure and preserve
its identity, strength, quality, and purity. 1 Section 121(c)(2) of the Modernization Act provides that
FDA cannot require the submission of a new drug application (NDA) or abbreviated new drug
application (ANDA) for a PET drug product until 2 years after the day we publish a final rule
establishing CGMP requirements for PET drug products. The final rule (21 CFR 212 (212 CGMP)) was

1
        Federal Food, Drug, and Cosmetic Act §§ 505(d) and 505(j)(4)(A) (21 U.S.C. §§ 355(d)(3) and 355(j)(4)(A))

DATE OF ISSUANCE                    09/11/2015                                                PART I - Page 1 of 2
FORM FDA 2438g (electronic-09/2003)

第 3 页

                                                                          PROGRAM          7356.002P

published December 10, 2009 (FR 74 at 65409) with an effective date of December 12, 2011.
Therefore, NDA’s and ANDA’s for PET drugs are required to be submitted by December 12, 2011.

In the same Federal Register, FDA announced the availability of a final Guidance for Industry entitled
“PET Drugs—Current Good Manufacturing Practice (CGMP)” (212 Guidance). This guidance is
intended to help PET drug producers better understand FDA’s thinking concerning compliance with the
PET 212 CGMP regulations. The guidance addresses resources, procedures, and documentation for all
PET drug production facilities, academic and commercial. In some cases, the guidance provides
practical examples of methods or procedures that PET drug production facilities can use to comply with
the CGMP requirements. Additional information can be obtained from the FDA PET Web site (see
references in Part VI).


The inspectional guidance in this program is structured to provide for efficient use of resources devoted
to routine surveillance and pre-approval inspection coverage. It also provides for follow-up compliance
coverage as needed.




DATE OF ISSUANCE                    09/11/2015                                    PART I - Page 2 of 2
FORM FDA 2438g (electronic-09/2003)

第 4 页

                                                                          PROGRAM          7356.002P

                                        PART II - IMPLEMENTATION


    A. OBJECTIVES

    The goal of this program's activities is to minimize consumers' exposure to adulterated PET drug
    products. Under this program, inspections and investigations, sample collections and analyses, and
    regulatory or administrative follow-up are made to:

        1) determine whether inspected firms are operating in compliance with applicable 212 CGMP
           requirements, and if not, to provide the evidence for actions to prevent adulterated products
           from entering the market and as appropriate to remove adulterated products from the market,
           and to take action against persons responsible as appropriate;

        2) provide a 212 CGMP assessment to determine the acceptability of a firm named in a pending
           new drug approval application; and,

        3) provide input to firms during inspections to improve their compliance with regulations.

    B. SCOPE

    Registration and Listing: All PET drug producers are required to register and list in accordance
    with existing requirements and guidance, except that PET drug facilities that only produce PET
    drugs for research purposes under an investigational new drug application (IND) or Radioactive
    Drug Research Committee (RDRC) are not required to register or list.

    Commercial Use: Commercial use means the use of a PET product for diagnosis not under an IND
    or under the review of a RDRC.

    Approval: After December 12, 2011, if the PET drug is produced for commercial distribution and
    use in humans for clinical practice to diagnose a patient, the maker of the PET drug must have
    submitted a new drug or abbreviated new drug application for that drug. A PET drug marketed
    prior to December 12, 2011 can continue to be marketed after the application is submitted.
    (See FDA Questions and Answers documents for further information:
    http://www.fda.gov/Drugs/DevelopmentApprovalProcess/Manufacturing/ucm085783.htm )

    PET Drug: The provisions of the Modernization Act concerning PET drugs, including the
    requirement that we establish appropriate CGMP requirements for PET drugs, do not apply to PET
    drugs used for therapeutic purposes. [FR 65414]

    A generator system that produces a PET radionuclide from the decay of a longer half-lived parent
    isotope is a nuclide generator under the definition of PET drug in section 201(ii)(2) of the act.
    Therefore, such generator systems are included in the definition of PET drug in § 212.1 and are
    subject to the CGMP requirements in part 212. As of the date of this program’s issuance, FDA has
    approved an NDA for a PET drug containing a generator (i.e., rubidium chloride RB-82 generator).
    [FR 65414]

DATE OF ISSUANCE                    09/11/2015                                        PART II - Page 1 of 5
FORM FDA 2438g (electronic-09/2003)

第 5 页

                                                                              PROGRAM          7356.002P


    PET Active Pharmaceutical Ingredients: The PET CGMP requirements are applicable to the
    production of a PET API as well as the finished PET drug product containing that API. When the
    regulation uses the term “PET drug” it means a “PET drug product” as defined in § 212.1, a PET
    API, and other PET ingredients. The term “PET drug product” refers ONLY to a finished dosage
    form of a PET drug, whether or not in association with one or more other ingredients. Only certain
    212 regulations apply to PET APIs (i.e., PET drugs). Please pay attention to the different uses of
    these terms when reviewing and applying these regulations.

    PET Intermediates: Although intermediates are excluded from the definition of active
    pharmaceutical ingredient, we wish to make clear that intermediates, as components of PET drugs,
    are subject to the PET CGMP regulations (see, e.g., § 212.40 on control of components, containers,
    and closures). [FR 65414]

    Investigational and Research PET Drugs: Important Note: The CGMP requirements followed
    for the study of PET drugs under an investigational new drug application (IND) or under the review
    of a Radioactive Drug Research Committee (RDRC) (which reviews and approves the use of
    radioactive drugs for certain limited research purposes in accordance with 21 CFR 361.1) may be
    either the regulations in 21 CFR 212 or the standards in USP Chapter <823>, “Radiopharmaceuticals
    for Positron Emission Tomography—Compounding” of the 32d ed. of the USP (2009) (USP 32).
    Inspections of PET drugs produced for research under the review of an RDRC, generally would be
    conducted on a for-cause basis only.

    Practice of Pharmacy or Medicine: PET drug production includes all operations to the point of
    final release of a finished dosage form. The dispensing of the patient unit doses from a multidose
    vial (does not apply if manufacturer’s marketed product is a unit dose vial) following the release of
    the finished dosage form is considered the practice of pharmacy and not covered under the PET
    CGMP regulations. Use of a PET drug product after receipt by a receiving facility generally is
    regarded as the practice of medicine and pharmacy. The fact that some production or
    ‘‘compounding’’ of PET drugs is performed by physicians, including some academicians and
    researchers at facilities located in universities and other not-for-profit institutions, does not remove
    such production from the scope of the PET CGMP regulations. The final rule ensures that the
    production of compounded PET drugs is subject to the CGMP regulations while permitting the
    dispensing and administration of PET drug products in accordance with State regulation of the
    practice of medicine and pharmacy. [FR 65411]

    Some short half-life PET drugs are individually “compounded” on-site, one dose at a time, for
    specific individual patients. There is no difference between compounding PET drugs and producing
    PET drugs. Having a very short half-life might mean that a PET drug could not be distributed to a
    facility outside of the one in which it was produced, but the product could still be produced, released
    for use, and administered to patients within the same facility. Please note that some of these PET
    drugs may not be required to have an approved application (see guidance: FDA Regulation of PET
    Products, Questions and Answers), but all are required to conform with the PET CGMP regulations.




DATE OF ISSUANCE                    09/11/2015                                            PART II - Page 2 of 5
FORM FDA 2438g (electronic-09/2003)

第 6 页

                                                                             PROGRAM         7356.002P

    Not for Profit: Although there are some differences between not-for-profit and commercial
    institutions, there is some overlap between the two, including when for-profit entities manage the
    production of PET drugs within not-for profit institutions. Not-for-profit versus for-profit status does
    not (and should not) have a significant bearing on the quality of PET drugs produced or the facilities
    and procedures needed to ensure product quality. The PET CGMP regulations also apply to not-for-
    profit institutions. [FR 65413]

    Additional terms are defined throughout this program if not already defined in the PET CGMP
    regulation at § 212.1 or related guidance.

    C. STRATEGY

    1) Routine Surveillance 212 CGMP Inspection of PET Producer Sites

        Routine surveillance inspections evaluate whether a PET drug production facility complies with
        the PET CGMP regulations. The routine surveillance of PET facilities also facilitates timely
        decisions on the application review process and in deciding government contracts.

    2) Pre-approval Inspection (PAI) of Producer Sites

        A pre-approval inspection (PAI) is performed to provide assurance that a PET drug production
        facility that is named in a PET New Drug Application (NDA) or Abbreviated New Drug
        Application (ANDA) is capable of producing the PET drug in accordance with CGMPs, and that
        the submitted application data are reliable, accurate, and complete.

    3) Compliance Inspections

        Compliance Inspections are inspections done to evaluate or verify corrective actions after a
        regulatory action has been taken. First, the coverage given in compliance inspections must be
        related to the areas found previously deficient and subject to corrective actions.

        The firm is expected to evaluate all of its operations and implement global corrective actions
        after a previously violative inspection, not just the deficiencies noted in the FDA Form 483. The
        Full Inspection Option should be used for a compliance inspection, especially if the Abbreviated
        Inspection Option was used during the violative inspection.

        For Cause Inspections are compliance inspections which are done to investigate a specific
        problem that has come to the attention of the agency. The problems may be indicated in Field
        Alert Reports (FARs), industry complaints, recalls, etc.

    D. PROGRAM MANAGEMENT INSTRUCTIONS

    The CGMP requirements for PET drugs differ in many significant ways from the CGMP
    requirements for non-PET drugs found in 21 CFR parts 210 and 211. The 212 CGMP
    requirements include differences concerning personnel; aseptic processing; quality control of
    components; self-verification of production steps; same-person oversight of production; batch record

DATE OF ISSUANCE                    09/11/2015                                          PART II - Page 3 of 5
FORM FDA 2438g (electronic-09/2003)

第 7 页

                                                                             PROGRAM          7356.002P

    review; authorization of product release; and labeling requirements. 21 CFR 212 simplifies the
    requirement for testing incoming materials and components used for manufacturing and provides
    more flexibility in the method for determining that each batch of a PET drug product conforms to
    specifications before final release. The 212 CGMP provides for circumstances under which
    conditional final release may be acceptable. See the Guidance for Industry on 212 CGMP for PET
    drugs.

    State of Control

    A PET drug producer is considered to be operating in a state of control when it employs conditions
    and practices that assure compliance with the intent of Section 501(a)(2)(B) of the Act and portions
    of the 212 CGMP regulations that pertain to its systems. A firm in a state of control produces
    finished PET drug products for which there is an adequate level of assurance of quality, strength,
    identity, and purity.

    A firm is out of control if any one system is out of control. A system is out of control if the quality,
    identity, strength, and purity of the products resulting from that/those system(s) cannot be
    adequately assured [21 CFR 212.2]. Documented 212 CGMP deficiencies provide the evidence for
    concluding that a system is not operating in a state of control. See Part V,
    Regulatory/Administrative Strategy, for a discussion of compliance actions based on inspection
    findings demonstrating out of control systems/firm.

    Inspection Planning

    District Offices will conduct PET drug production inspections and maintain profiles. District
    Offices are responsible for determining the depth of coverage given to each drug firm in accordance
    with this program. However, abbreviated inspections are encouraged where appropriate.
    Inspectional coverage in accordance with this program will provide sufficient assessment of the state
    of compliance for each firm. The frequency and depth of inspection should also be determined by
    the statutory obligation, the firm's compliance history, the technology employed, and the resources
    made available to inspect PET facilities. When a system is inspected, the inspection of that system
    may be considered applicable to all products that use it. Investigators should select an adequate
    number and type of products to accomplish coverage of the system. Selection of products should be
    made so that coverage is representative of the firm's overall abilities in production within the 212
    CGMP requirements.

    Inspection Teams

    An inspection team (See IOM 5.1.2.5) may be composed of experts from within the District, other
    Districts, or Headquarters (CDER or ORA). Contact ORA/Office of Medical Products and
    Tobacco Operations if technical assistance or additional expertise is needed (see also FMD 142).
    Participation of an analyst (chemist or microbiologist) with knowledge of PET drugs on the
    inspection team is also encouraged, especially where laboratory issues are extensive or complex.
    Contact your Drug Servicing Laboratory or ORA/Office of Regulatory Science.

    Profiles

DATE OF ISSUANCE                    09/11/2015                                           PART II - Page 4 of 5
FORM FDA 2438g (electronic-09/2003)

第 8 页

                                                                             PROGRAM          7356.002P



    The inspection findings will be used as the basis for updating the profile class in the profile section
    of the FACTS EIR coversheet that is used to record profile/class determinations. All PET drug
    inspections should use Industry code 65 and Profile Class code “PET.”

    Note: There is only one Profile Class “PET” for PET drugs.




DATE OF ISSUANCE                    09/11/2015                                           PART II - Page 5 of 5
FORM FDA 2438g (electronic-09/2003)

第 9 页

                                                                            PROGRAM          7356.002P

                                           PART III - INSPECTIONAL

    A. GENERAL

    Review and use the 212 CGMPs to evaluate production processes. The investigator should conduct
    inspections according to the STRATEGY section in Part II of this compliance program.

    PET Guidance for Industry documents are not to be referred to as the justification for an inspectional
    observation. Guidance documents do not establish requirements. They state examples of ways to
    meet requirements. Current Guides to Inspection and Guidance for Industry provide interpretations
    of requirements, which may assist in the evaluation of the adequacy of 212 CGMP systems.

    Important safety notice: During an inspection of a PET manufacturing facility, the investigator will
    be exposed to ionizing radiation. Please refer to the IOM section 1.5.4.2.3 for additional
    information. It is also advisable that the investigator attend the RH102 Basic Radiation Safety
    training program prior to the inspection. Each investigator who visits a manufacturer of radioactive
    products or tests ionizing radiation emitting products must wear a Pager and aThermo Luminescent
    Dosimeter (TLD) to estimate external exposure to radiation. Consult your supervisor or other
    District Office management for information on obtaining a Pager and TLDs.

    Current inspectional observation policy as stated in the IOM says that the FDA-483, when issued,
    should be specific and contain only significant items. The investigation team will prepare a narrative
    establishment inspection report (EIR) per instructions in the IOM (Chapter 5).

    Review of NDA/ANDA files may assist in selecting significant drug processes and critical process
    parameters for coverage in the various systems. Significant drug processes include those that
    contain steps with unique or difficult manipulation in the performance of a step that may affect drug
    quality. Aseptic processing is considered significant and should be covered. Inspections for this
    compliance program may be performed during visits to a firm when operations are being performed
    for other compliance programs or other investigations.

    Unlike other commercial production facilities, PET production facilities generally employ a few
    operators each of whom must perform certain operations and checks quickly without disruption so
    that the drug product can be distributed promptly to pharmacies and waiting patients. For this
    reason, District Offices are to schedule PET inspections in advance with the firm to allow the facility
    time to ensure appropriate staff is available to enable an efficient and complete inspection. When
    scheduling the inspection with the firm, the investigator may obtain information about the planned
    times of key operations and time their arrival accordingly. “For cause” inspections need not be
    scheduled in advance. The investigator may also need to accommodate the typical PET
    establishment’s early hours of operation.




DATE OF ISSUANCE                    09/11/2015                                       PART III - Page 1 of 19
FORM FDA 2438g (electronic-09/2003)

第 10 页

                                                                             PROGRAM          7356.002P


    B. INSPECTION APPROACHES

    This program provides two options for surveillance and PAI inspections: Full Inspection Option and
    Abbreviated Inspection Option.

    For the first two years of the program, a full inspection option is required for routine
    surveillance purposes (a PAI may be abbreviated). After the first two years (starting FY14), an
    abbreviated inspection option should be determined as described below:

    1) Selecting the Full Inspection Option.

        The Full Inspection Option is a surveillance or compliance inspection to provide broad and in-
        depth evaluation of a firm's 212 CGMP compliance. The Full Inspection Option is an
        inspection of at least four of the systems, one of which must be the Quality System and
        include coverage of the aseptic processing controls. Some firms may use a contract testing
        laboratory for microbiological tests (e.g., sterility test). In these cases, the inspection of four
        systems, when Laboratory Control System is selected, will comprise the inspection of the entire
        firm and will be considered the Full Inspection Option.

        a) Select the Full Inspection Option for an initial FDA inspection of a facility under this
           program.

        b) Select the Full Inspection Option when the firm has a history of fluctuating into and out of
           compliance. To determine if the firm meets this criterion, the District should utilize all
           information at its disposal, such as inspection results, results of sample analyses, complaints,
           DQRS reports, recalls, etc. and the compliance actions resulting from them or from past
           inspections. A Full Inspection may revert to the Abbreviated Inspection Option, with District
           concurrence, based on prior history findings of no objectionable conditions as listed in Part V
           in all six systems (abbreviated inspection involves auditing fewer records and evaluations).

        c) Evaluate if important changes have occurred by comparing current operations against the
           EIR for the previous Full Inspection. The following types of changes are typical of those that
           warrant the Full Inspection Option:

             i) New potential for microbial contamination or cross-contamination arising through
                change in procedures or product line (e.g., new manufacturing equipment, new aseptic
                processing station).

            ii) Use of new technology requiring new expertise, significant new equipment, or new
                facilities.

           iii) A significant change in aseptic processing method or technique.

            iv) A significant change in personnel at the site when there is a limited number of employees
                at the PET producer facility.

DATE OF ISSUANCE                    09/11/2015                                        PART III - Page 2 of 19
FORM FDA 2438g (electronic-09/2003)

第 11 页

                                                                            PROGRAM          7356.002P


        d) A Full Inspection may also be conducted on a surveillance basis at the District's discretion as
           resources permit.

        e) The Full Inspection Option will satisfy the biennial inspection requirement.

        f) Follow up to a Warning Letter or other significant regulatory actions should generally be a
           Full Inspection.

    2) Selecting the Abbreviated Inspection Option.

        The Abbreviated Inspection Option is a surveillance or compliance inspection meant to provide
        an efficient update evaluation of a firm's conformance to 212 CGMPs. The abbreviated
        inspection will provide documentation for continuing a firm in a satisfactory 212 CGMP
        compliance status. Generally this will be done when a firm has a record of satisfactory 212
        CGMP compliance, with no significant recalls, or product defect or alert incidents, or with little
        shift in the production profiles of the firm in the time since the last inspection.

        The Abbreviated Inspection Option is an inspection of the Quality System and aseptic
        sterility controls and one additional system.

        a) This option involves an inspection of the manufacturer to maintain surveillance over the
           firm's activities and to provide input to the firm on maintaining and improving the CGMP
           level of assurance of quality of its products.

        b) An Abbreviated Inspection may revert to the Full Inspection Option, with District
           concurrence, based on findings of objectionable conditions as listed in Part V. However, an
           Abbreviated Inspection may be sufficient to justify regulatory action without the need for a
           Full Inspection.

        c) The Abbreviated Inspection Option is adequate for routine coverage and will satisfy the
           biennial inspectional requirement.

    3) PAI Inspection Coverage

        The PAI inspection may be covered under the Abbreviated Inspection Option

        a) The Abbreviated Inspection Option is adequate for routine coverage and will satisfy the PAI
           inspectional requirement.

        b) A Full Inspection may also be conducted at the District's discretion when serious non-
           compliance is uncovered.




DATE OF ISSUANCE                    09/11/2015                                       PART III - Page 3 of 19
FORM FDA 2438g (electronic-09/2003)

第 12 页

                                                                            PROGRAM          7356.002P


    C. SYSTEM INSPECTION COVERAGE

    1) QUALITY SYSTEM (21 CFR 212.10, 212.20, 212.50, 212.61, 212.71, 212.100) WITH
       ASEPTIC STERILITY CONTROLS (21 CFR 212.30, 212.60, 212.70)

        The review of the Quality System is of major importance in the manufacture of PET drugs since
        the drugs are produced in low volumes and typically administered prior to the completion of
        sterility testing. Assessment of the Quality System is performed in three phases. The first phase
        is to evaluate whether the quality unit has fulfilled the responsibility to review and approve all
        procedures related to production, quality control, and quality assurance and assure the
        procedures are adequate for their intended use. This also includes the associated recordkeeping
        systems. The second phase is to assess the data collected to identify quality problems and may
        link to other major systems for inspectional coverage. The third phase is to evaluate the aseptic
        sterility controls: sterility test results; bacterial endotoxins test performed on each production
        batch; integrity test of the membrane filter used for aseptic fill; environmental monitoring
        program (viable and non-viable monitoring and the corrective plan when action levels are
        exceeded); aseptic fill and media fill procedures; and growth promotion testing of microbial
        media [212.60(b)].

        For each of the following, the firm should have written and approved procedures, and associated
        documentation verifying performance. The firm's adherence to written procedures should be
        verified through observation whenever possible. These areas are not limited to finished products,
        but may also incorporate components and in-process materials. These areas may indicate
        deficiencies not only in this system but also in other systems that may warrant more in-depth
        coverage. All areas under this system should be covered; however, the depth of coverage may
        vary depending upon inspectional findings.

        a) Production records should be reviewed, which may include investigations of non-conforming
           product. Records should include corrective action where appropriate.

        b) Complaints concerning quality or purity of a PET drug product, or possible adverse reactions
           should be documented, investigated, and followed up. Review the firm's response to any
           complaints.

        c) There should be a sufficient number of trained/qualified employees who have the necessary
           education, background, training, and experience to perform their assigned functions and to
           manufacture the number of batches each day. (Note: Documentation for training should
           demonstrate they are capable of their assigned function(s) (i.e., radiopharmacy, chemistry,
           and aseptic procedures needed for drug manufacture).)

        d) Change control should be approved or rejected. Change control procedures must be
           established and followed.

        e) Review the reprocessing records and confirm the firm followed reprocessing procedures
           stated in the product’s approved application. If a PET drug is reprocessed, the reprocessed

DATE OF ISSUANCE                    09/11/2015                                       PART III - Page 4 of 19
FORM FDA 2438g (electronic-09/2003)

第 13 页

                                                                                PROGRAM           7356.002P

             batch must meet established specifications, except for sterility, before release. (Note:
             Typically, sterile filtration will be the only reprocessing step in the event of a failed integrity
             test.)

        f) Ensure the firm has a written stability testing program. [212.61] Investigate the cause of any
           non-conforming product. [212.71(a)]

        g) Evaluate records and written procedures for quarantined and rejected components,
           containers, and closures.

        h) The dispensing of patient unit doses under the practice of pharmacy is not covered under 212
           CGMP. However, personnel operating in the nuclear pharmacy may also be conducting
           batch release or quality operations and these operations would be regulated under 212
           CGMP.

        i) Evaluate whether the firm has sufficient controls to prevent administration of product to a
           patient by recalling a product that has been shipped before final release if it fails to conform
           to established specifications.

        ASEPTIC STERILITY CONTROL

        Inspection of the aseptic processing of the PET drug differs from that for a conventional large-
        scale aseptic production operation. The depth of aseptic processing coverage should be risk-
        based, which means focusing on the most critical process parameters and quality attributes.
        Aseptic processing is a critical part of PET drug production and is considered minimally required
        coverage for a PET inspection. In addition to the Quality System, all areas listed below should
        be covered; the depth of coverage should be sufficient to verify the firm is producing a safe and
        sterile product.

        a) Sterility Testing (Note: sterility testing must be initiated within 30 hours after completion of
           production and is not required to be completed prior to product release. Thirty hours may be
           exceeded over weekends or holiday. If the sample is held longer than 30 hours, the firm
           must demonstrate that the longer period does not adversely affect the sample and the test
           results.)

             i) If sterility testing is performed by an outside laboratory, report the laboratory name and
                address.

            ii) If sterility testing is performed in-house, assess whether the personnel are qualified to
                perform sterility testing and assess the results.

           iii) The firm should have adequate written procedures for the sampling and testing of
                products for sterility, endotoxins, particulate matter (by visual examination), and other
                appropriate tests.

            iv) Review sampling, testing, and sterility records for selected drug products. Determine if

DATE OF ISSUANCE                    09/11/2015                                            PART III - Page 5 of 19
FORM FDA 2438g (electronic-09/2003)

第 14 页

                                                                               PROGRAM          7356.002P

                 sampling and testing were performed appropriately, and that results were within
                 specifications (i.e., within the established acceptance criteria).

            v) Describe the firm's procedures for evaluating batches that fail the initial sterility test.
               How are "false positives" determined? If the cause of a sterility failure cannot be
               determined as arising from the production environment or laboratory error, what decision
               is made by the firm concerning the release of the lot in question? Is the firm taking
               action to correct any identified problems to prevent recurrence of a nonconforming
               product or other quality problem?

        b) Endotoxins Testing

             Determine that a bacterial endotoxins test was performed on each batch or initial sub-batch
             of a PET drug product. The product can be distributed under control after a pharmacopeial
             bacterial endotoxin test is initiated. However, the endotoxin results should meet the
             acceptance criteria before administering the product to humans (for further information see
             212 Guidance, p. 30). Distribution under control does not constitute final release of the
             product; final release can only occur after the completion of the laboratory determination to
             ensure conformance to specifications (except for sterility). Distribution control procedures,
             including any agreements between the PET drug producer and receiving facilities, should be
             specified in a standard operating procedures (SOPs) document. [212.90; 212 Guidance, p. 32;
             212 Final Rule (FR), p. 65419]

             For PET drugs with very short-lived radionuclides, the bacterial endotoxins test on the initial
             sub-batch must be completed before the release of subsequent sub-batches for human
             administration. [212.70(c); 212 Guidance, p. 30; 212 FR, p. 65419]

        c) Dilution of the PET Drug Product Batch Vial

             Evaluate that the PET drug solution obtained from a synthesizer in the final product vial
             assembly is diluted under sterile conditions to ensure that it meets the quality and purity
             characteristics it is supposed to have in the final formulation solution.

             Aseptic manipulations should be performed within the aseptic hood. As such the final
             product vial assembly (everything that is post sterile filter and including the sterile filter)
             should be assembled in an aseptic hood using aseptic techniques. If a firm uses a pre-
             production approach and stores the assembled product vials prior to use, the maximum hold
             time for maintaining the sterility of the product vials should be validated. Verify that all
             entries into the sterile final product vial are done using aseptic technique, as follows:

             i) The non-sterile side of the sterile filter can be connected to the synthesizer unit outside of
             aseptic hood. The dilution of the product to make the final formulated drug product solution
             can be performed outside of the aseptic hood through an intact sterile filter that has been pre-
             attached to the final product vial assembly under aseptic conditions.

             ii) Alternatively, direct dilution into the sterile final product vial should be performed in an

DATE OF ISSUANCE                    09/11/2015                                          PART III - Page 6 of 19
FORM FDA 2438g (electronic-09/2003)

第 15 页

                                                                                  PROGRAM           7356.002P

             aseptic hood.

        d) Facility/ equipment and environmental controls (ref.: 212 Guidance)

             If the firm uses the following equipment, it is recommended that they do the following:

                 i) Aseptic Workstation

                        When an aseptic workstation is used, it is recommended that:

                         1. The laminar airflow velocities be monitored periodically at the work surface as
                            well as at the HEPA filter face to ensure adequate uniformity of flow
                            throughout the critical area. This is typically performed during the workstation
                            certification, but some units may measure the pressure differential of the filter
                            to ensure appropriate airflow.

                         2. For aseptic equipment and facilities, the disinfectants used should be purchased
                            sterile or sterile filtered by the firm.

                         3. All aseptic manipulations should be performed under environmental conditions
                            that minimize the possibility of contamination (e.g., Class 100 in the laminar
                            flow hood; clean and controlled environment in the hot cell).

                 ii) Sterilizing Filters

                        Evaluate how the firm is determining the integrity of the membrane filter used for
                        aseptic fill. Filter units used to sterilize PET drugs should be subjected to the
                        manufacturers' recommended integrity tests such as a bubble point test described in
                        the application or SOP. The filter should be documented to be intact and not
                        damaged. Determine that the filter integrity test was performed after completion of
                        filtration of the PET drug product and before release of the PET drug for human
                        administration.

                        When sterilizing filters are used in manufacturing PET drugs, we recommend
                        performing the following during an inspection [see CPGM 7356.002A, Sterile Drug
                        Process Inspections]:

                         1. Evaluate the firm's procedure in response to a filter that fails post-filtration
                            testing.

                         2. Determine if investigations were performed following filter failures.

                         3. If bubble point test is used to verify the integrity of the sterilizing filter,
                            evaluate the operator’s competence in performing a bubble point test.



DATE OF ISSUANCE                    09/11/2015                                              PART III - Page 7 of 19
FORM FDA 2438g (electronic-09/2003)

第 16 页

                                                                                  PROGRAM          7356.002P

                iii) Aseptic Filling

                        For PET drugs produced in batch vials, the assembly of the sealed/sterile batch
                        production vial is performed under aseptic conditions prior to the start of
                        manufacturing.

                        When encountered during an inspection, we recommend performing the following:

                         1. Describe in the EIR the aseptic filling processes from preparation of bulk liquid
                            product to filling and sealing of final dosage form, including the environmental
                            monitoring performed in critical areas during actual production.

                              (1) Evaluate the firm’s environmental monitoring program. Guidance
                                  recommends that environmental monitoring of the aseptic workstation be
                                  performed periodically. In addition, it is recommended that
                                  microbiological monitoring in the aseptic workstation be conducted using
                                  settling plates during or contact plates after critical aseptic processes and
                                  sterility testing.

                              (2) Aseptic processing should be performed under environmental conditions
                                  that minimize the possibility of contamination. Evaluate if Class 100
                                  conditions are maintained. It must be acknowledged that
                                  radiopharmaceutical “hot cells” may not be ISO classified. However, the
                                  hot cell should be a clean and controlled area. Aseptic preparation of
                                  containers and other product components (filters, syringes and needles)
                                  should be done in a Class 100 laminar flow workstation.

                         2. Review microbiological monitoring data for several representative months of
                            production, including the period during which batches of the selected drug
                            product were prepared. Verify that results were within the limits established; if
                            results exceeded limits, evaluate firm’s response.

                iv) Media fill (Guidance: Media Fills for Validation of Aseptic Preparations for PET
                    Drugs)

                        The media fill is a critical part of the validation to ensure the facility is capable of
                        producing sterile PET drugs by aseptic processing.

                        When encountered during an inspection, we recommend performing the following:

                        1. Determine if the aseptic filling procedure was qualified by a media fill
                           procedure.

                        2. Evaluate if the media fill simulates the aseptic processing for a routine
                           production run. (The use of vials assembled in advance of actual fill should be
                           evaluated under the worst-case storage period in the media fill study.) Report if

DATE OF ISSUANCE                    09/11/2015                                             PART III - Page 8 of 19
FORM FDA 2438g (electronic-09/2003)

第 17 页

                                                                               PROGRAM          7356.002P

                            the media fill procedures were followed and the results, including:

                            (1) Number of runs performed;
                            (2) Number of vials/syringes filled per run;
                            (3) Sizes of vials, syringes, and fill volume;
                            (4) Media used;
                            (5) Positive controls;
                            (6) Incubation periods;
                            (7) Incubation temperatures; and,
                            (8) Results.

                        3. Evaluate whether the firm investigated result of failed media fills and instituted
                           corrective actions.

                        4. Review results of media fills performed; verify that results are acceptable.

                        5. Evaluate if all appropriate personnel were included in the media fill program.

                        6. Evaluate the growth promotion testing of media used in the media fill
                           simulations. It is necessary to conduct a growth promotion test on media fill
                           media to verify that the media supports bacterial growth.

                            Commercially prepared media should be used within the label’s shelf life and
                            stored according to the label’s recommendations. Only qualified vendors
                            should be used.

                        7. Incoming environmental monitoring plates should be checked to confirm
                           identity and physical integrity upon receipt. Only qualified vendors should be
                           used.

                        8. Review the temperatures and incubation time records used to incubate media fill
                           samples.

                        9. Evaluate whether the microorganisms from positive vials were identified
                           according to genus.

                        10. Evaluate if the firm determines that such microorganisms correlated to those
                            found during environmental monitoring.


    2) FACILITIES AND EQUIPMENT SYSTEM (21 CFR 212.30)

        When this system is selected for coverage, all areas listed below should be covered; however, the
        depth of coverage may vary depending upon inspectional findings. For PET facilities typically
        the same area or room may be organized for multiple operations, such as manufacturing,
        laboratory, and aseptic controls. The same individuals may be performing multiple operations.

DATE OF ISSUANCE                    09/11/2015                                          PART III - Page 9 of 19
FORM FDA 2438g (electronic-09/2003)

第 18 页

                                                                           PROGRAM          7356.002P

        The dispensing of patient unit doses under the practice of pharmacy is not covered under 212
        CGMP. However, personnel operating in the nuclear pharmacy may be conducting batch release
        or quality operations and these operations would be regulated under 212 CGMP.

        This system includes the measures and activities which provide an appropriate physical
        environment and resources used in the production of the PET drug. It includes:

        a) Facilities adequate to ensure the orderly handling of materials and equipment, prevention of
           mix-ups, and prevention of contamination of equipment or product (see 212 Guidance, VI.B,
           p. 8).

        b) Equipment procedures for maintenance, cleanliness, suitability for intended purposes.
           Equipment should be properly installed, maintained, and capable of repeatedly producing
           valid results (see 212 Guidance: VI.C.1, p. 10). Activities in accordance with procedures
           must be documented.

        c) Equipment construction and maintenance contact surfaces are not reactive, additive, or
           absorptive.

        d) The firm's adherence to written procedures should be verified through observation whenever
           possible. These areas may indicate deficiencies not only in this system but also in other
           systems that would warrant more in depth coverage.

        e) Although the cyclotron is included in the definition of a PET drug, the cyclotron used to
           manufacture the radioisotopes for PET drugs is not to be physically inspected due to the
           complexity of the instrumentation and health hazards. The maintenance records of the target
           window (including target window rebuild) may be reviewed to identify problem encountered,
           and corrective actions. Normally, attention is devoted to this issue if a quality problem has
           been identified.

        f) All testing, measuring, monitoring equipment (e.g., thermometer, thermocouple systems,
           pressure gauges, pH meter) used in production should be maintained and calibrated (212
           Guidance: VI.C, p. 10). This would include the automated radiochemical synthesis unit that
           is used to produce the PET drug product. Depending on the application and the process,
           certain production equipment may be of single use, such as resin cartridges used in
           purification. In some applications, the connective tubing may be single use and must be
           replaced for each production run.

        g) Checked to ensure cleanliness and suitability immediately before use. Records of these
           checks must be kept

        PET Drug Generator Systems

                   The use of nuclide generators, such as 82Rb or 62Cu generator, may pose special
                   concerns. When encountered during an inspection, we recommend reporting the
                   following information:

DATE OF ISSUANCE                    09/11/2015                                      PART III - Page 10 of 19
FORM FDA 2438g (electronic-09/2003)

第 19 页

                                                                             PROGRAM          7356.002P


                   1. Quality control procedures used in the assembly, testing and re-use of the
                      generator-system regarding the following areas:
                          (1) Assay;
                          (2) Calibration;
                          (3) Sterility;
                          (4) Endotoxins control;
                          (5) pH;
                          (6) Contaminants (radioactive and non-radioactive) eluting from the generator;
                          (7) Reproducibility of daily elution pattern; and,
                          (8) Evaluation of parent radioisotope breakthrough at the end of elution to
                              ensure levels are within the recommended limits.

                   2. Any use of bacteriostatic agents in the preparation of eluting solutions.

                   3. Instructions provided the user as to the assembly, operation and maintenance of
                      sterility.

                   4. Determine the manufacturer of the generator and the source and purity of the
                      radioactive materials used.


    3) MATERIALS SYSTEM (21 CFR 212.10, 212.20, 212.40)

        This system includes measures and activities to control finished products, components, including
        water or gases that are incorporated into the product, containers and closures. It includes
        inventory control processes, drug storage, distribution controls, and records.

        The firm must have written procedures describing the receipt, log-in, identification, storage,
        handling, testing, and acceptance or rejection of components and containers and closures. The
        procedures must be adequate to ensure that they are suitable for their intended use. The firm's
        adherence to written procedures should be verified through observation.

        Note: Only certain 212 regulations apply to PET APIs, as indicated herein.

         In addition to the Quality System and aseptic sterility controls, when this system is selected for
        coverage, all areas listed below should be covered; however, the depth of coverage may vary
        depending upon inspectional findings.

        a) Inert gases are commonly used to pressurize the chemical synthesis unit and facilitate the
           flow of components. The gases may also be used for the evaporation of solvents. These
           gases come in contact with the drug product and should be filtered.

        b) Component, container, and closure suppliers are qualified.

        c) Components are handled and stored in a manner that prevents contamination, mix-ups, and

DATE OF ISSUANCE                    09/11/2015                                        PART III - Page 11 of 19
FORM FDA 2438g (electronic-09/2003)

第 20 页

                                                                             PROGRAM          7356.002P

             deterioration.

        d) Storage under quarantine until tested or examined and released.

        e) For containers and closures: Representative samples of each lot must be examined for
           conformity to written specifications. A visual identification is required of each lot.

        f) If finished product testing is not conducted that ensures that the correct components have
           been used, at least one identity test must be conducted on each lot of each component that
           yields an active ingredient and each lot of an inactive ingredient used in that PET drug
           product. Note: If a PET facility uses an inactive ingredient that is an approved product and
           marketed as a finished drug product intended for intravenous administration (for example,
           sterile saline), then an identity test on an inactive ingredient is not required. Refer to 21 CFR
           212.40 (c) (1) (ii).

             i) For solvents or reagents, that are not the subject of finished-product testing, it must be
                determined that each lot complies with written specifications by examining a certificate
                of analysis provided by the supplier.

            ii) If a component is used to prepare an inactive ingredient on site, then an identity test must
                be performed on the components used to make the inactive ingredient before the
                components are released for use.

           iii) Appropriate retesting/reexamination of components.

        g) If finished product testing is conducted to ensure that the correct components were used, then
           each lot of components must comply with written specifications by examining a certificate of
           analysis, and an identity test is not required.

        h) Components, containers, and closures appropriately designated (i.e., quarantined, accepted,
           or rejected).

        i) Control system for implementing changes in the materials handling operations to include
           demonstrating that any change does not adversely affect the identity, strength, quality, or
           purity of a PET drug.

        j) Documented results of any investigation.

        k) Components, containers, and closures include:

            i) Closures, syringes, needles, tubing, etc.

           ii) Packaging materials.

          iii) Chemicals and other raw materials used in manufacturing, such as saline solution, buffers,
               radiochemicals, kits for chemistry stations, etc.

DATE OF ISSUANCE                    09/11/2015                                        PART III - Page 12 of 19
FORM FDA 2438g (electronic-09/2003)

第 21 页

                                                                              PROGRAM          7356.002P


           iv) Radionuclides (radioactive isotopes).


    4) PRODUCTION SYSTEM (21 CFR 212.10, 212.20, 212.50, 212.70)

        This system includes measures and activities to control the production of PET drugs including
        batch production, in-process sampling and testing, and process verification, if required. It also
        includes establishing, following, and documenting performance of approved production
        procedures.

        Note: Production includes all operations to the point of final release of a finished dosage form.
        The use of a PET drug product after receipt by a receiving facility generally is regarded as the
        practice of medicine and pharmacy. [212 FR, p. 65411]

        Note: PET CGMPs distinguishes batches from sub-batches for requirements related to process
        verification and conformance to specifications.

        Although a low radiochemical yield would not necessarily require the rejection of a batch, low
        radiochemical yield can be a useful predictor of control of the production process for a PET
        drug. For example, a low radiochemical yield might result from a leak in the production system
        that introduces an extraneous substance, resulting in a contaminated product that might not be
        easily purified. Repeated occurrences of low radiochemical yield or a downward trend in
        radiochemical yield should prompt an investigation and, if necessary, corrective action.
        Exceeding the radiochemical yield limits would require investigation and corrective action but
        not necessarily rejection of the batch. [212.50; 212 Guidance, p. 19; 212 FR, p. 65416]

        PET drug product specifications consist of critical and non-critical (or key) attributes.
        Measurements of critical quality attributes are essential because they are indicative of the
        product’s safety and effectiveness. Examples of critical attributes include appearance,
        radiochemical identity and purity (including chiral purity when applicable), assay (including
        radioconcentration), specific activity (the radioactivity at a specific time per unit mass of the
        element or of the chemical in the PET drugs in mCi/ug or mCi/umole), radioactive and non-
        radioactive impurities, pH, bacterial endotoxin, and membrane filter integrity.

        However, there may be attributes of a PET drug product that, although not as significant as those
        included in the specifications, are nevertheless important in assessing the quality of the product.
        Examples of these noncritical attributes might include radionuclidic purity (when potentially
        contaminating radionuclides do not impact the safety or effectiveness of the drug product), as
        well as certain low-level nontoxic impurities and class three residual solvents. These noncritical
        attribute tests, referred to as periodic quality indicator tests (PQITs), are additional to tests
        conducted for conformance to drug product specifications. A PQIT is performed at
        predetermined intervals rather than on a batch-to-batch basis. A PET drug producer generally
        establishes and refines tests of noncritical attributes within its internal quality system. However,
        the sponsor of a PET drug product should seek approval of a PQIT for a noncritical attribute in
        the product’s marketing application. FDA will review the frequency of PQIT testing during

DATE OF ISSUANCE                    09/11/2015                                         PART III - Page 13 of 19
FORM FDA 2438g (electronic-09/2003)

第 22 页

                                                                             PROGRAM          7356.002P

        CGMP inspections. [212 FR, p. 65418]

        The firm should have written and approved procedures and documentation to ensure that all key
        process parameters are controlled and that any deviations are justified. The firm's adherence to
        written procedures should be verified through observation whenever possible. In addition to the
        Quality System and aseptic sterility controls, when this system is selected, all areas listed below
        should be covered; however, the depth of coverage may vary depending upon inspectional
        findings.

        a) Process changes should be approved before they are implemented. Change control
           procedures must be established and followed.

        b) Reprocessing a batch is only appropriate if reprocessing procedures are stated in the
           product’s approved application.

        c) Identification of all major equipment used in production

        d) Master production and control records that document all steps in the production process

             Note: Reasonable variations are permitted in the amount of component necessary if they are
             specified in the master production and control records (212.50(b)(5)).

        e) Batch production and control records

             Each time a batch of a PET drug is produced, a unique batch production and control record
             must be created. Batch records may be stored either in hard copy or on the firms’ computer
             system or network. The batch record should provide complete traceability to the lots used in
             the batch production, and identify procedures used and personnel involved in the
             performance of each critical step and in the testing and approval of a batch.

        f) Production area and equipment is clean and suitable for use

        g) Control of in-process materials until testing/verification activities have been completed or
           approvals are received and documented

        h) Process verification

             i) For a PET drug for which each entire batch undergoes full finished-product testing to
                ensure that the product meets all specifications, process verification is not required.

            ii) When the results of the production of an entire batch of a PET drug are not fully verified
                through finished-product testing or when only the initial sub-batch in a series is tested,
                the PET drug producer must demonstrate that the process for producing the PET drug is
                reproducible and is capable of producing a drug product that meets the predetermined
                acceptance criteria. Process verification activities and results must be documented.


DATE OF ISSUANCE                    09/11/2015                                        PART III - Page 14 of 19
FORM FDA 2438g (electronic-09/2003)

第 23 页

                                                                             PROGRAM          7356.002P

        i) Production records must be reviewed by the person responsible for QA to determine if errors
           have occurred.

        j) Production components (ref.: 212 Guidance)

             If certain components (e.g., ion exchange columns / cartridges) are preassembled in bulk for
             use over a period of time, then make sure their production and storage conditions are
             appropriate to prevent microbial growth and contamination.

             If production is performed using different chemical synthesis equipment, verification studies
             should be performed for each type of equipment.


    5) PACKAGING AND LABELING SYSTEM (21 CFR 212.10, 212.20, 212.50, 212.80)

        This system includes measures and activities that control the packaging and labeling of PET
        drugs and drug products. It includes label examination [212.80(b)], storage, handling,
        distribution and use, and controls to prevent labeling and product mix-ups.

        In addition to the Quality System and aseptic sterility controls, when this system is selected for
        coverage, all areas listed below should be covered; however, the depth of coverage may vary
        depending upon inspectional findings.

        a) Packaging and labeling changes should be approved or rejected. Change control procedures
           must be established and followed.

        c) The product should be packaged and labeled to protect the product from alteration,
           contamination, and damage.

        d) Labels must be applied so they remain legible and affixed during the conditions of
           processing, storage, handling, distribution, and use.

        e) Master production and control records must include a description of containers, closures,
           packaging materials, and contain a specimen or copy of each label and all other labeling.

        f) The batch production record must include labeling.

        g) Packaging and labeling operations must be controlled to prevent mix-ups (i.e., examination
           and reconciliation of issued labels).


    6) LABORATORY CONTROL SYSTEM (21 CFR 212.10, 212.20, 212.60, 212.61, 212.70)

        This system includes measures and activities related to laboratory procedures, sampling, testing,
        analytical methods development and verification, and the stability program.


DATE OF ISSUANCE                    09/11/2015                                        PART III - Page 15 of 19
FORM FDA 2438g (electronic-09/2003)

第 24 页

                                                                              PROGRAM          7356.002P

        Suitable identification of the sample means information that will provide complete traceability of
        the sample to the batch or lot from which the sample was taken. A PET drug producer might be
        able to meet this requirement by referring to information in the master production and control
        record or the batch production and control record. The information needed to identify a sample
        might vary depending on the circumstances under which production and testing are conducted.
        [212 FR, p. 65417, comment 29]

        For each of the following, the firm should have written and approved procedures for the conduct
        of each test, and documentation of the results. The firm's adherence to written procedures should
        be verified through observation whenever possible. In addition to the Quality System and
        Aseptic Sterility Controls, when this system is selected for coverage, all areas listed below
        should be covered; however, the depth of coverage may vary depending upon inspectional
        findings.

        a) Methods, specifications, and procedure changes should be approved before they are
           implemented. Change control procedures must be established and followed.

        b) Procedures should ensure that laboratory equipment is clean, suitable for its intended
           purposes, properly installed, maintained, and capable of repeatedly producing valid results.
           Activities must be documented in accordance with these procedures.

        c) Procedures should be written to ensure that laboratory equipment is routinely calibrated,
           inspected, and maintained. The activities must be documented in accordance with these
           procedures.

        d) Determine that sampling and testing procedures ensure that components and in-process
           materials conform to appropriate standards.

        e) Complete analytical records from all tests and statement of the results of tests including the
           date and time the test was conducted. Documentation should include a statement that the test
           results compare with established acceptance criteria.

        f) Establishment of a written stability testing program for each finished PET drug product,
           including reliable, meaningful, and specific test methods (212.61; note that APIs and other
           components of PET drugs are not subject to this regulation). The stability samples must be
           representative of the lot or batch from which they were obtained and should be checked to
           verify conformance to the approved drug application stability conditions (see 212 Guidance,
           p. 27). The radioconcentration (at end of synthesis) of the batches routinely produced should
           be below the radioconcentration (at end of synthesis) of the batches tested for stability.

        g) Refer to the specific compendia requirements and approved application for the PET drug
           product requirements for final release. These tests may include microbiological, chemical,
           endotoxins, and radionuclidic and radiochemical identity and purity tests performed.

        h) Evaluate method validation and/or verification. When a test method is developed at a site
           other than the production and testing facility, as is often the case for multi-site firms, the

DATE OF ISSUANCE                    09/11/2015                                         PART III - Page 16 of 19
FORM FDA 2438g (electronic-09/2003)

第 25 页

                                                                              PROGRAM          7356.002P

             method transfer and verification protocol and report should be evaluated.

             Notes: For conditional final release [212.70(f)], if a malfunction prevents the performance of
             a radiochemical identity/purity test or prevents the determination of the product’s specific
             activity, the product must not be released.

             Conditional final release may be appropriate if the PET drug producer cannot complete one
             of the required finished-product tests for a PET drug product because of a malfunction
             involving analytical equipment, rather than solely a complete breakdown of such equipment
             [212.70(f); 212 FR, p. 65420, comment 34].

             Further background information is provided for easy reference:

                 1. USP does not require the completion of every pharmacopeial test on each product
                    batch prior to release of the batch. Instead, the USP states that every article, when
                    tested, should conform to the monograph. However, § 212.70(c) requires that the
                    PET drug producer conduct an appropriate laboratory determination to ensure that
                    each batch of a PET drug product conforms to specifications, except for sterility,
                    before final release of the product. Laboratory tests for critical product attributes must
                    be completed before final release. Conditional final release must not be approved if
                    the malfunction involving analytical equipment prevents the performance of a
                    radiochemical identity/purity test or prevents the determination of the product’s
                    specific activity.

                 2. However, a PET drug producer may allow conditional final release if the PET drug
                    producer cannot complete one of the required finished-product tests for a non-critical
                    attribute of a PET drug product because of a malfunction involving analytical
                    equipment, rather than solely a complete breakdown of such equipment. Conditional
                    release should be extremely infrequent and meets the criteria as specified in the PET
                    CGMP regulations (§ 212.70(f)(1)).

                 3. For example, gas chromatography equipment might be operating but producing
                    inaccurate results because of some malfunction. Conditional release due to an
                    equipment malfunction might be appropriate when test results are atypical but other
                    process indicators show that release of raw materials and production and purification
                    process events have occurred as expected. Or, for example, a PET drug producer
                    might observe a baseline drift in HPLC analysis for a product, but if the peak shape is
                    similar to what is normally seen and the production and purification events have
                    progressed as expected, it might be reasonable to conclude that there is an equipment
                    malfunction, rather than that the product is contaminated. In such a case, conditional
                    final release of the product would be appropriate.

                 4. A reserve sample must be retained of the conditional release batch.

                 5. If an out-of-specification result is obtained when testing the reserve sample, the firm
                    must immediately notify the receiving facility.

DATE OF ISSUANCE                    09/11/2015                                         PART III - Page 17 of 19
FORM FDA 2438g (electronic-09/2003)

第 26 页

                                                                              PROGRAM          7356.002P


                 6. The firm must document all testing, notifications, and corrective actions to prevent
                    recurrence involving the malfunction of the analytical equipment.

                 7. Another batch of PET product must not be released until the problem is corrected
                    concerning the malfunction and the omitted finished product test is completed.

                 8. It is not appropriate to allow conditional final release when there is an ‘‘inconclusive
                    result’’ or an ‘‘invalid condition,’’ because those terms are so broad and vague that
                    they might permit conditional final release when there is too much uncertainty about
                    the safety and quality of the drug product. It is not appropriate to allow each PET
                    drug producer to determine which finished product tests may be omitted under
                    conditional final release. It is not necessary to require that the approved application
                    specify all the tests that need not be completed for conditional final release, as long as
                    conditional final release is limited to circumstances in which there is a malfunction
                    involving analytical equipment.

                 9. As for radionuclidic purity, it is possible to conduct the test on a decayed sample of
                    the product. We recommend that PET drug producers develop alternate tests for
                    specifications for which they conclude it is not possible to conduct a particular test
                    after an analytical equipment malfunction has been corrected. For example, if a dose
                    calibrator malfunctioned and the activity of a product could not be assayed, a sample
                    of known dilution could be counted using other equipment, and the activity
                    concentration could be determined by correcting for counting efficiency and dilution.

        h) The identity, purity, and quality of reagents, solutions and supplies used in testing procedures
           must be adequately controlled and properly labeled with expiration dates. Where appropriate,
           a CoA for each lot of incoming material should be inspected against the firm’s current
           specification (refer to materials section). Verify the appropriate storage and use of the
           reagents according to the manufacturer’s expiration date.

        i) Determine that analytical methods are suitable for their intended use and are sufficiently
           sensitive, specific, accurate, and reproducible.

        j) Ensure test records are complete in accordance with 212.60(g).

        k) All instruments used in laboratory operations should be identified. Any changes in
           instrumentation should be noted on successive inspections.

        l) Laboratory Equipment typically seen in PET facilities:

               i) High-Performance Liquid Chromatograph (HPLC)

                        If the firm chooses to use an HPLC, it is recommended that they do the following:



DATE OF ISSUANCE                    09/11/2015                                         PART III - Page 18 of 19
FORM FDA 2438g (electronic-09/2003)

第 27 页

                                                                               PROGRAM         7356.002P

                        1. That the HPLC system has detectors suitable for the intended purpose and be of
                           sufficient sensitivity. Generally UV and radiochemical detectors are used.
                           Ensure that the radiochemical detector is used within the specified operating
                           range.

                        2. That prior to each day of use, the analysts perform a system suitability test (212
                           Guidance, p. 13)

                        3. That the column be stored in a suitable solvent that is compatible with the
                           column and will inhibit microbial growth. Refer to the drug application for
                           specific details.

              ii) Dose Calibrator

                   It is an appropriately calibrated ionization chamber used to measure the total amount of
                   radioactivity in a PET drug to be administered to a patient. To assure that dose
                   calibrator is reading correctly, see the manufacturers’ instructional manual (see 212
                   Guidance, p. 14).

              iii) Radiochromatographic Scanner

                   It is used to measure radiochemical purity. Radiochemical purity is that proportion of
                   the total radioactivity that is present in the desired chemical form of the radioactive
                   substance in the PET drug. Typically, a PET drug producer will use a
                   radiochromatographic scanner to measure the radioactivity distribution in a developed
                   thin layer or paper chromatographic medium. It is recommended that they follow the
                   manufacturers’ recommended checks and maintenance (212 Guidance, p. 14).

              iv) Multichannel Analyzer (MCA)

                   It is used to measure radionuclidic purity and identity. Radionuclidic purity is that
                   proportion of the total radioactivity present in the specified radionuclide of the
                   radioactive substance in the PET drug at a specific time. Typically, a PET drug
                   producer will use a MCA (212 Guidance, p. 14).

               v) Gas Chromatograph (GC)

                   It is used to measure residual solvents in the drug product (212 Guidance, p. 13).




DATE OF ISSUANCE                    09/11/2015                                         PART III - Page 19 of 19
FORM FDA 2438g (electronic-09/2003)

第 28 页

                                                                             PROGRAM          7356.002P



                                            PART IV - ANALYTICAL


    A. ANALYZING LABORATORIES

    No analytical activities are planned under this program. It is not anticipated that samples will
    normally be collected for PET radioisotopes; however, for-cause investigations may require
    sampling. Refer to the for-cause assignment for instructions on sampling, if any.




DATE OF ISSUANCE                    09/11/2015                                          PART IV - Page 1 of 1
FORM FDA 2438g (electronic-09/2003)

第 29 页

                                                                             PROGRAM          7356.002P


                      PART V - REGULATORY/ADMINISTRATIVE STRATEGY

    Inspection findings that demonstrate that a firm is not operating in a state of control may be used as
    evidence for taking appropriate advisory, administrative and/or judicial actions. When it is
    consistent with the public protection responsibilities of the agency and the nature of the violation is
    significance, formal agency regulatory actions will be recommended.

    The instructions outlined in the Regulatory Procedures Manual (RPM) should be followed.
    Regulatory recommendations should be submitted to CDER Office of Pharmaceutical Quality
    (OPQ), Office of Surveillance (OS) via electronic copy (e.g., doc, pdf files, etc.) using the “Mission
    Accomplishment and Regulatory Compliance Services-Compliance Management Services”
    (MARCS-CMS) link located on the Inside FDA’s IT Application Page under ORA Applications.

    Regulatory options include Warning Letters, injunctions and prosecutions. In most cases, seizure or
    recall of small batches of short-lived radioactive drug products will not be feasible because they are
    dispensed so quickly. Refusal to approve (21 CFR 314.125 or 314.127) or withdrawal of approval
    (21 CFR 314.150) of an NDA or a supplemental NDA is an additional option.

    The District Office will consider all of the inspectional, analytical, administrative, voluntary and
    regulatory follow-up options available when a violative situation is encountered. When deciding the
    type of action to recommend, the initial decision should be based on the significance of the
    violation(s), the firm’s compliance history and the most effective way to protect consumers. The
    District Office should proactively initiate regulatory discussions with CDER OPQ/OS and the
    ORA/Office of Enforcement and Import Operations (OEIO) prior to the formal submission of a
    regulatory recommendation.

    A. REGULATORY ACTION

    1) The following should be used in recommending an appropriate regulatory action to
       CDER/ OPQ/OS:

        Under section 501(a)(2)(B) of the act, a PET drug is adulterated unless it is produced in
        compliance with 21 CFR 212.

        Exceptions: Provisions of USP Chapter <823> apply when PET drugs are produced under:

                 •   Investigational New Drug Application (IND)
                 •   Radioactive Drug Research Committee (RDRC)

    2) Major deviations from CGMPs

        Evidence to support significant and/or a trend of deficiencies within a system covered could
        demonstrate the failure of a system and should result in consideration of the issuance of a
        Warning Letter, Untitled Letter, or other judicial action by the District. When deciding the type


DATE OF ISSUANCE                    09/11/2015                                           PART V - Page 1 of 2
FORM FDA 2438g (electronic-09/2003)

第 30 页

                                                                               PROGRAM          7356.002P

        of action to recommend, the initial decision should be based on the risk to the public health
        and/or the frequency of the problem.

        Districts should prepare and submit an advisory or judicial action recommendation for any firm
        that demonstrates serious violations causing their products to be adulterated under section
        501(a)(2)(B) of the Act [21 USC ~ 351(a)(2)(B)]. Significant violations are outlined below:

        a) Failure to reject a batch of PET drug product that did not conform to specifications
           [212.71(a)]
        b) Failure to establish finished product release specifications [212.70(a)]
        c) Failure to complete finished product testing (except for sterility) for final release [212.70(c)]
        d) Release and distribution of product that does not meet specifications [212.70(d)]
        e) Failure to establish a written stability testing program for each finished PET drug product
           [212.61(a)]
        f) Failure to establish master and/or batch production and control records [212.50(b) and (c)]
        g) Significant facilities or equipment deficiencies impacting aseptic filling conditions and/or
           product safety and quality [212.30(a) and (b)]
        h) Failure to utilize the appropriate sterilizing filter to ensure quality and purity [212.20(a)]

        i) Failure to perform an integrity test on the membrane filter used for aseptic fill [212.50(c)]
        j) Failure to investigate batches that fail the sterility test [212.70(e)]
        k) Failure to notify all facilities that received product that failed to meet sterility [212.70(e)]

        l) Failure to perform a bacterial endotoxins test on each batch or initial sub-batch of a PET drug
           product [212.70(a) and (c)]

        m) Failure to perform media fills for the aseptic filling procedure as appropriate to ensure
           product quality and purity [212.50]
        n) Failure to evaluate the generator to ensure that the parent radioisotope breakthrough is within
           the recommended product quality and purity specifications [212.50]

        o) Failure to perform growth promotion testing (i.e., media supports bacterial growth) at
           prescribed time points [212.60(b)].




DATE OF ISSUANCE                    09/11/2015                                             PART V - Page 2 of 2
FORM FDA 2438g (electronic-09/2003)

第 31 页

                                                                              PROGRAM           7356.002P

           PART VI - REFERENCES, ATTACHMENTS, AND PROGRAM CONTACTS


    A. REFERENCES:


    1) PET CGMP regulations: Code of Federal Regulations, Title 21, Part 212

    2) PET CGMP Final Rule: Federal Register: December 10, 2009 (Volume 74, Number 236),
       Page 65409-65436 (includes preamble and general comments explaining the final PET CGMP
       regulations)
        http://www.regulations.gov/#!documentDetail;D=FDA-2004-N-0449-0003

    3) Guidance: PET Drugs – Current Good Manufacturing Practice (CGMP)
        http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM070306.pdf

    4) Guidance for Industry: Sterile Drug Products Produced by Aseptic Processing
        http://www.fda.gov/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/ucm064971.htm

    5) Basic Radiation Safety Course, RH102 (FDA/ORA, Division of Human Resource Development
       (DHRD) (see IOM section 1.5.4.2.3)

    6) Guidance: FDA Regulation of PET Products: Questions and Answers
        http://www.fda.gov/Drugs/DevelopmentApprovalProcess/Manufacturing/ucm085783.htm

    7) Guidance: Media Fills for Validation of Aseptic Preparations for PET Drugs
        http://www.fda.gov/downloads/Drugs/GuidanceComplianceRegulatoryInformation/Guidances/UCM273766.pdf




DATE OF ISSUANCE                    09/11/2015                                            PART VI - Page 1 of 2
FORM FDA 2438g (electronic-09/2003)

第 32 页

                                                                             PROGRAM            7356.002P


    B. PROGRAM CONTACTS

     ORA
      Office of Medical Products and Tobacco Operations (OMPTO)
        ORAHQDrugInspectionPOC@fda.hhs.gov

        Office of Regulatory Science Telephone:
        (301) 796-6600

     Center for Drug Evaluation and Research
     CGMP or any Quality-Related Policy Questions
     For CGMP or any quality-related policy question, technical or scientific questions or
     information needs, including questions about this program, please send an email to the
     following address and it will be handled as a top priority:

     CDER-OPQ-Inquiries@fda.hhs.gov

     Enforcement-Related Guidance or Policy
     For enforcement-related guidance or policy, including evidence need and sufficiency, citations,
     and case evaluation/recommendation advice, please send an email
     to the following address and it will be handled as a top priority:

     CDER OMQ Compliance Policy: CDEROMQCompliance@fda.hhs.gov

     Labeling Requirements and Policies
     Office of Unapproved Drugs and Labeling Compliance, see intranet home page for contacts
     [CDER | Office of Compliance | Office of Unapproved Drugs and Labeling Compliance]

     Registration and Drug Listing Requirements
     CDER Office of Compliance, see “CDER: Who’s the Lead” intranet page for contacts
     [CDER | Office of Communications | CDER: Who’s the Lead]




DATE OF ISSUANCE                    09/11/2015                                            PART VI - Page 2 of 2
FORM FDA 2438g (electronic-09/2003)

第 33 页

                                                                          PROGRAM         7356.002P


                                  PART VII - CENTER RESPONSIBILITIES


        CENTER FOR DRUG EVALUATION AND RESEARCH

        OPQ/OS will conduct periodic evaluations in order to assess the effectiveness of this program.

        Please send any comments on the operation and efficiency and direct any questions regarding
        application of the program to the Quality Management System (QMS). The QMS complaint and
        feedback form should be the appropriate response for feedback on efficiency or operation of this
        program.




DATE OF ISSUANCE                    09/11/2015                                      PART VII - Page 1 of 1
FORM FDA 2438g (electronic-09/2003)